E-cigarettes are gaining popularity in the U.S. as well as in other global markets. Currently, limited published analytical data characterizing e-cigarette formulations (e-liquids) and aerosols exist. While FDA has not published a harmful and potentially harmful constituent (HPHC) list for e-cigarettes, the HPHC list for currently regulated tobacco products may be useful to analytically characterize e-cigarette aerosols. For example, most e-cigarette formulations contain propylene glycol and glycerin, which may produce aldehydes when heated. In addition, nicotine-related chemicals have been previously reported as potential e-cigarette formulation impurities. This study determined e-liquid formulation impurities and potentially harmful chemicals in aerosols of select commercial MarkTen(®) e-cigarettes manufactured by NuMark LLC. The potential hazard of the identified formulation impurities and aerosol chemicals was also estimated. E-cigarettes were machine puffed (4-s duration, 55-mL volume, 30-s intervals) to battery exhaustion to maximize aerosol collection. Aerosols analyzed for carbonyls were collected in 20-puff increments to account for analyte instability. Tobacco specific nitrosamines were measured at levels observed in pharmaceutical grade nicotine. Nicotine-related impurities in the e-cigarette formulations were below the identification and qualification thresholds proposed in ICH Guideline Q3B(R2). Levels of potentially harmful chemicals detected in the aerosols were determined to be below published occupational exposure limits.
U.S. FDA draft guidance recommends reporting quantities of designated harmful and potentially harmful constituents (HPHCs) in e-cigarette e-liquids and aerosols. The HPHC list comprises potential matrix-related compounds, flavors, nicotine, tobacco-related impurities, leachables, thermal degradation products, and combustion-related compounds. E-cigarettes contain trace levels of many of these constituents due to tobacco-derived nicotine and thermal degradation. However, combustion-related HPHCs are not likely to be found due to the relatively low operating temperatures of most e-cigarettes. The purpose of this work was to use highly sensitive, selective, and validated analytical methods to determine if these combustion-related HPHCs (three aromatic amines, five volatile organic compounds, and the polycyclic aromatic hydrocarbon benzo[a]pyrene) are detectable in commercial refill e-liquids, reference e-cigarette e-liquids, and aerosols generated from rechargeable e-cigarettes with disposable cartridges (often referred to as "cig-a-likes"). In addition, the transfer efficiency of these constituents from e-liquid to aerosol was evaluated when these HPHCs were added to the e-liquids prior to aerosol formation. This work demonstrates that combustion-related HPHCs are not present at measurable levels in the commercial and reference e-liquids or e-cigarette aerosols tested. Additionally, when combustion-related HPHCs are added to the e-liquids, they transfer to the aerosol with transfer efficiencies ranging from 49% to 99%.
Exposure to diacetyl (DA) has been linked to the respiratory condition bronchiolitis obliterans. Previous research has demonstrated that DA and other α-dicarbonyl compounds can be detected in both the e-liquids and aerosols of e-vapor products (EVPs). While some EVP manufacturers may add these compounds as flavor ingredients, the primary objective of this work was to determine the potential for the formation of α-dicarbonyl compounds during the generation of aerosols from EVPs where no DA or other α-dicarbonyl compounds are added to the e-liquid. A novel ultraperformance liquid chromatography-mass spectrometry-based analytical method for the determination of DA, acetyl propionyl, glyoxal, and methylglyoxal was developed and validated. Next, eight commercially available cig-a-like-type EVPs were evaluated for α-dicarbonyl formation. Increased levels of α-dicarbonyls were observed in the aerosols of all evaluated EVPs compared to their respective e-liquids. Mechanistic studies were conducted using a model microwave reaction system to identify key reaction precursors for DA generated from propylene glycol (PG) and carbon-13-labeled glycerin (GLY). These studies, along with the corresponding retrosynthetic analysis, resulted in the proposed formation pathway where hydroxyacetone is generated from PG and/or GLY. Hydroxyacetone then participates in an aldol condensation with formaldehyde where formaldehyde can also be generated from PG and/or GLY; the resultant product then dehydrates to form DA. This proposed pathway was further investigated through in situ synthetic organic experiments within the model microwave reaction system. This work establishes that DA is formed in the aerosol generation process of the EVPs tested though at levels below toxicological concern.
The USA Food and Drug Administration (FDA) established benzo[a]pyrene (B[a]P) as a harmful and potentially harmful constituent (HPHC) found in tobacco products. Tobacco manufacturers are required to report HPHC quantities to the FDA; however, there is currently no standardized method for determination of B[a]P in smokeless tobacco products (STPs). This work details a sensitive, selective and rapid method for the determination of B[a]P in STPs, cigarette filler and tobacco. Tobacco is extracted using methanol followed by solid-phase extraction and concentration prior to analysis by gas chromatography/mass spectrometry in the selected ion monitoring mode. Cooperation Centre for Scientific Research Relative to Tobacco reference products and 3R4F Kentucky reference cigarette filler were used for method validation. All method validation requirements were met including linearity, accuracy, precision, robustness, limit of detection (LOD) and limit of quantitation (LOQ), and stability. Calibration range of 0.5-125 ng mL-1 was achieved with the coefficient of determination (R2) greater than 0.995. The method LOQ and LOD were 0.729 and 0.216 ng/g, respectively. Using standardized methods for the measurement of HPHCs in tobacco products will reduce variability and ensure accurate data for regulatory reporting.
Recent reports have suggested that (1) formaldehyde levels (measured as a hydrazone derivative using the DNPH derivatization method) in Electronic Nicotine Delivery Systems (ENDS) products were underreported because formaldehyde may react with propylene glycol (PG) and glycerin (Gly) in the aerosol to form hemiacetals; (2) the equilibrium would shift from the hemiacetals to the acetals in the acidic DNPH trapping solution. In both cases, neither the hemiacetal nor the acetal would react with DNPH to form the target formaldehyde hydrazone, due to the lack of the carbonyl functional group, thus underreporting formaldehyde. These reports were studied in our laboratory. Our results showed that the aerosol generated from formaldehyde-fortified e-liquids provided a near-quantitative recovery of formaldehyde in the aerosol, suggesting that if any hemiacetal was formed in the aerosol, it would readily hydrolyze to free formaldehyde and, consequently, form formaldehyde hydrazone in the acidic DNPH trapping solution. We demonstrated that custom-synthesized Gly and PG hemiacetal adducts added to the DNPH trapping solution would readily hydrolyze to form the formaldehyde hydrazone. We demonstrated that acetals of PG and Gly present in e-liquid are almost completely transferred to the aerosol during aerosolization. The study results demonstrate that the DNPH derivatization method allows for an accurate measurement of formaldehyde in vapor products.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.