Fasting plasma glucose is a useful test for the screening of both subcategories of gestational diabetes, a threshold of 85 mg/dl being an acceptable option. Effective screening for the subcategory diabetes can be achieved using a cut point of 89 mg/dl. If greater emphasis is placed on the detection of impaired glucose tolerance, a lower value, 81 mg/dl, may be needed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.