Understanding of the exact topography of the distal radioulnar ligaments insertions remains limited. An anatomical study was performed in 21 fresh frozen cadaveric wrists, where the superficial and deep ligaments were sequentially transected sharply at their ulnar insertions. The relationships between the distal radioulnar ligament footprints relative to the bony landmarks of the ulnar styloid were digitized. Our study demonstrated that in the coronal plane, the superficial distal radioulnar ligaments inserted at an average of 87% of the styloid height proximally to the styloid tip distally. The deep distal radioulnar ligaments inserted at an average of 81% of the styloid height distally to the fovea proximally. The superficial footprint had an area of 10.6 mm2 on the ulnar styloid. The deep distal radioulnar ligaments attachment was asymmetric and generally had two separate footprints. This study adds important topographical knowledge about the footprint of the distal radioulnar ligaments and may contribute to understanding the consequences of ulnar styloid fractures and distal radioulnar ligaments lesions.
Purpose The acetabular reinforcement ring with a hook (ARRH) has been designed for acetabular total hip arthroplasty (THA) revision. Additionally, the ARRH offers several advantages when used as a primary implant especially in cases with altered acetabular morphology. The implant facilitates anatomic positioning by placing the hook around the teardrop and provides a homogenous base for cementing the polyethylene cup. Therefore, the implant has been widely used in primary total hip arthroplasty at our institution. The present study reports the long-term outcome of the ARRH after a minimum follow-up of 20 years. Methods Two hundred and ten patients with 240 primary THAs performed between April 1987 and December 1991 using the ARRH were retrospectively reviewed after a minimum follow-up of 20 years. Twenty-three of 240 hips were lost to follow-up, 110 patients with 124 THAs had deceased without having a revision surgery performed. This left 93 hips for final evaluation. Of those, 75 hips were assessed clinically and radiographically after a mean follow-up of 23.1 years (range 21.1-26.1 years). In 18 cases, clinical and radiographic assessment was omitted because implant revision had been performed prior to the follow-up investigation. The primary endpoint was defined as revision for aseptic loosening. Results Out of the 93 hips available for final evaluation, 14 hips were revised for aseptic loosening; another four were revised for other reasons (deep infection n = 2, recurrent dislocation n = 2). The survival probability of the cup was 0.96 (95% confidence interval 0.93-0.99) after 20 years with aseptic loosening as endpoint. Radiographic analysis of the surviving 75 hips showed at least one sign of radiographic loosening in 24 hips. The mean Merle d'Aubigne score increased from 8 points pre-operatively to 15 points at final follow-up (7.5 ± 1.8 vs 15.0 ± 2.3, p < 0.001). The mean HHS was 85 ± 14 at final follow-up. Radiographic loosening did not correlate with the clinical outcome. Conclusions The long-term results of the ARRH in primary THA are comparable to results with standard cemented cups and modern cementless cups. We believe that the ARRH is a versatile implant for primary THA, especially in cases with limited acetabular coverage and altered acetabular bone stock where the ARRH provides sufficient structural support for a cemented cup.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.