Water–oil separation is important in the oil industry, as the incorrect classification of oil can lead to losses in the production and have an environmental impact. This paper proposes the use of fiber Bragg grating (FBG) temperature sensor array to identify the oil in water–emulsion–oil systems, using only the temperature responses for oil classification results in operational and economic benefits. To demonstrate the possibility of using the FBG temperature sensor to classify oil level, the temperature distribution of an oil storage tank, with 2 m height and 0.8 m in diameter, is simulated using thermal distribution models. Then, the temperature effect in a 2 m long FBG array with a different number and distribution of FBGs is simulated using the transfer matrix method. In each case, we extract the wavelength shift (Δλ), total width at half the maximum (FWHM) and the location of the FBG in the fiber. For the oil classification, we dichotomized the fluids into oil and non-oil (water and emulsion). Due to the low separability of the classes, the random forest algorithm was chosen for classification, starting with 200 FBG equidistant sensors and decreasing to 6, with different distributions along the fiber. As expected, the highest accuracy occurs with the 200 FBGs array (96%). However, it was possible to classify the oil with an accuracy of 94.89% with only 8 FBGs, using tests for two proportions (with a significance of 5%); the accuracy of 8 FBGs is the same as of 50 FBGs.
This paper proposed a liquid level measurement and classification system based on a fiber Bragg grating (FBG) temperature sensor array. For the oil classification, the fluids were dichotomized into oil and nonoil, i.e., water and emulsion. Due to the low variability of the classes, the random forest (RF) algorithm was chosen for the classification. Three different fluids, namely water, mineral oil, and silicone oil (Kryo 51), were identified by three FBGs located at 21.5 cm, 10.5 cm, and 3 cm from the bottom. The fluids were heated by a Peltier device placed at the bottom of the beaker and maintained at a temperature of 318.15 K during the entire experiment. The fluid identification by the RF algorithm achieved an accuracy of 100%. An average root mean squared error (RMSE) of 0.2603 cm, with a maximum RMSE lower than 0.4 cm, was obtained in the fluid level measurement also using the RF algorithm. Thus, the proposed method is a feasible tool for fluid identification and level estimation under temperature variation conditions and provides important benefits in practical applications due to its easy assembly and straightforward operation.
The assessment of heat transfer is a complex task, especially for operations in the oil and gas industry, due to the harsh and flammable workspace. In light of the limitations of conventional sensors in harsh environments, this paper presents a fiber Bragg grating (FBG)-based sensor for the assessment of the heat transfer rate (HTR) in different liquids. To better understand the phenomenon of heat distribution, a preliminary analysis is performed by constructing two similar scenarios: those with and without the thermal insulation of a styrofoam box. The results indicate the need for a minimum of thermal power to balance the generated heat with the thermal losses of the setup. In this minimum heat, the behavior of the thermal distribution changes from quadratic to linear. To assess such features, the estimation of the specific heat capacity and the thermal conductivity of water are performed from 3 W to 12 W, in 3 W steps, resulting in a specific heat of 1.144 cal/g °C and thermal conductivity of 0.5682 W/m °C. The calibration and validation of the HTR sensor is performed in a thermostatic bath. The method, based on the temperature slope relative to the time curve, allowed for the measurement of HTR in water and Kryo 51 oil, for different heat insertion configurations. For water, the HTR estimation was 308.782 W, which means an uncertainty of 2.8% with the reference value of the cooling power (300 W). In Kryo 51 oil, the estimated heat absorbed by the oil was 4.38 kW in heating and 718.14 kW in cooling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.