BACKGROUND
The safety and efficacy of the first generation of the Pipeline Embolization Device (PED; Medtronic Inc) have been proven in large case series. Ischemic events are one of the most common complications following treatment of aneurysms with flow diverters. The new PED Flex with Shield technology (PED Shield; Medtronic Inc) was introduced to minimize the rate of complications.
OBJECTIVE
To evaluate the outcomes of patients harboring aneurysms treated with the PED Shield.
METHODS
This was an observational, prospective, single-arm multicenter study of patients treated with the PED Shield. The primary safety endpoint was the absence of major neurological complications and death. The secondary effectiveness endpoint was angiographic occlusion at 6 and 12 mo. Technical complications were also reported.
RESULTS
Between November 2017 and December 2018, 151 patients from 7 centers with 182 aneurysms were enrolled. The mean aneurysm size was 7.0 mm; 27 (14.8%) aneurysms were large, and 7 (3.8%) were giant. In 141 of 151 patients (93.4%), the primary endpoint was reached. The overall rate of periprocedural complications was 7.3%. Of the aneurysms, 79.7% met the study's secondary endpoint of complete occlusion at 6 mo and 85.3% at 12 mo.
CONCLUSION
The PED Shield is a safe and effective treatment for intracranial aneurysms. The results regarding total occlusion and ischemic complications did not differ from those obtained in case series using previous versions of the PED. Long-term follow-up and comparative studies are required to provide stronger conclusions regarding the reduced thrombogenicity of this device.
In circumferential aneurysms treated with stent-assisted coil embolization, packing density is the main predictor of complete occlusion. In this type of aneurysm, a packing density of ≥19% was enough to reach complete occlusion; knowing this is important to avoid higher packing densities that have more risk.
Conservative management of ruptured spontaneous dissecting spinal aneurysms is a reasonable therapeutic option capable of achieving favorable angiographic and clinical outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.