In this multicenter retrospective study, the outcomes of 836 patients with myelodysplastic syndrome (MDS) who underwent transplantation with a human leukocyte antigen (HLA)-identical sibling donor were analyzed according to 2 types of conditioning: reduced-intensity conditioning (RIC) in 215 patients, and standard myeloablative (or high-dose) conditioning (SMC) in 621 patients. In multivariate analysis, the 3-year relapse rate was significantly increased after RIC (hazard ratio [HR], 1.64; 95% confidence interval [95% CI], 1.2-2.2; P ؍ .001), but the 3-year nonrelapse mortality (NRM) rate was decreased in the RIC group (HR, 0.61; 95% CI, 0.41-0.91; P ؍ .015). The 3-year probabilities of progression-free and overall survivals were similar in both groups (39% after SMC vs 33% in RIC; multivariate P ؍ .9; and 45% vs 41%, respectively; P ؍ .8). In conclusion, the lower 3-year NRM after RIC is encouraging, since these patients were older (age > 50 years in 73% RIC vs 28% in SMC, P < .001) and had more adverse pretransplantation variables. However, based on the higher risk of relapse, patients with no contraindications for SMC should not receive RIC outside of prospective randomized trials, which are needed to establish the position of RIC-based transplantation in the treatment of patients with MDS. (Blood. 2006;108:836-846)
Randomized studies testing the clinical efficacy of platelet additive solutions (PASs) for storage of platelets are scarce and often biased by patient selection. We conducted a multicenter, randomized study to investigate clinical efficacy of platelets stored in PAS II versus plasma, also including patients with clinical complications associated with increased platelet consumption. A total of 168 evaluable patients received pooled buffy coatderived platelet concentrates (PCs) suspended in either plasma (n ؍ 354) or PAS II (n ؍ 411) stored up to 5 days. Both univariate as well as multivariate analysis showed a significant effect of used storage medium in regard to 1-and 24-hour count increments and corrected count increments, in favor of plasma PCs. However, there were no significant differences between the groups regarding bleeding complications and transfusion interval. Adverse transfusion reactions occurred significantly less after transfusions with PAS II PCs (P ؍ .04). Multivariate analysis showed no significant effect of the used storage medium on the incidence of 1-and 24-hour transfusion failure. We showed safety and efficacy of PAS II PCs in intensively treated patients; however, plasma PCs show superior increments. (Blood. 2006;108:3210-3215)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.