The paper describes the analytical potentialities of the trinuclear chromium(III) complexes as potentiometric ionophores for the construction of electrodes sensitive to the presence of nitrate anion. The electroactive material containing 4,4’-bipyridil was synthesized in situ. The membrane was prepared using dioctylphthalate as a solvent mediator and poly (vinyl chloride) as a polymeric matrix. The electrodes presented a slope of 56 mV/decade, a low limit of detection (3,2.10-6 mol/l), an adequate lifetime (4 months), and suitable selectivity characteristics when compared with other nitrate electrodes. The good parameters of this electrode made possible its application to the determination of nitrate in different types of fertilizers.
The polarographic behavior of the complex formed by V(V) and 2,3–dihydroxybenzaldehyde (2,3–DHBA) in the solution containing acetate buffer (pH 5,2) has been investigated. By means of a.c. polarography, chronovoltammetry and other techniques, it has been shown that the electrode process is complicated by the adsorption of 2,3-DHBA and its vanadium complex. The kinetic and adsorption parameters of the electrode process have been determined: adsorption equilibrium constant B= 1,32⋅105 mol-1⋅dm3, the attraction constant γ = 1,2, the maximum surface concentration Гmax = 9,10⋅10-11 mol⋅ cm-2; the share of the electrode surface occupied by one particle of the adsorbed complex S = 1,81 nm2 and the free adsorption energy ΔG = - 39,1 kJ· mol-1.
A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11. The working concentration range of the electrode is 1.10-5 – 1.10-1 mol/l with a detection limit of 5.10-6 mol/l. The sensor has a response time of 20 s and can be used for at least 6 months without any considerable fluctuation of the potential. The selectivity coefficients determined at using the fixed interference method indicate a good discriminating ability towards other anions. The prepared sensor was applied as an indicator electrode in the titration of thiocyanate with Ag+.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.