Background: Liver and spleen are the most common injured organs in abdominal blunt trauma which can lead to life threatening bleeding. Fast and reliable evaluation of these injuries is important to manage them immediately. In this study, the level of agreement between multidetector CT-Scan and surgical findings is evaluated. Methods: Multidetector CT-scan and explorative laparotomy of the patients with blunt abdominal trauma were assessed retrospectively. Characteristics of the injuries were categorized on the basis of the American Association for the Surgery of Trauma (AAST) grading system and the findings were analyzed using kappa test. Results: The findings of 35 patients were analyzed. According to the kappa test, there were "Moderate" agreement between CT-Scan and surgery in evaluation of lacerations, location and AAST grade of splenic injuries, and disagreement in evaluation of splenic hematoma. In assessment of lacerations and AAST grading of hepatic injuries, there was only "Fair" agreement between CT-Scan and surgery. Conclusions: Multidetector CT-Scan is an appropriate method for evaluating splenic and hepatic blunt trauma, even more accurate than surgery in some limited cases. However, only "Moderate" and "Fair" agreements, indicate that initial measures such as history taking and abdominal physical examination, specifically for unstable patients that they not have enough time to do CT-Scan, should be properly considered before using this method. Furthermore, in case of other organ injuries, CT-Scan can be an appropriate method for prioritizing other damages to splenic and hepatic injuries or vice versa, on the basis of intensity, characteristics and the grade of injury. This is an abstract presented in the 33rd Iranian congress of radiology (ICR) and the 15th congress of Iranian radiographic science association (IRSA)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.