Background: Endocardial pacemaker leads and right ventricular (RV) pacing are well-known causes of tricuspid valve, mitral valve, and cardiac dysfunction. Lead-related adverse consequences can potentially be mitigated by leadless pacemaker (LP) therapy by eliminating the presence of a transvalvular lead. This study assessed the impact of LP placement on cardiac and valvular structure and function. Methods: Echocardiographic studies before and 12±1 months after LP implantation were performed between January 2013 and May 2018 at our center and compared with age- and sex-matched controls of dual-chamber transvenous pacemaker recipients. Results: A total of 53 patients receiving an LP were included, of whom 28 were implanted with a Nanostim and 25 with a Micra LP device. Tricuspid valve regurgitation was graded as being more severe in 23 (43%) patients at 12±1 months compared with baseline ( P <0.001). Compared with an apical position, an RV septal position of the LP was associated with increased tricuspid valve incompetence (odds ratio, 5.20; P =0.03). An increase in mitral valve regurgitation was observed in 38% of patients ( P =0.006). LP implantation resulted in a reduction of RV function, according to a lower tricuspid annular plane systolic excursion ( P =0.003) and RV tricuspid lateral annular systolic velocity ( P =0.02), and a higher RV Tei index ( P =0.04). LP implantation was further associated with a reduction of left ventricular ejection fraction ( P =0.03) and elevated left ventricular Tei index ( P =0.003). The changes in tricuspid valve regurgitation in the LP group were similar to the changes in the dual-chamber transvenous pacemaker control group (43% versus 38%, respectively; P =0.39). Conclusions: LP therapy is associated with an increase in tricuspid valve dysfunction through 12 months of follow-up; yet it was comparable to dual-chamber transvenous pacemaker systems. Furthermore, LP therapy seems to adversely impact mitral valve and biventricular function.
BACKGROUND Idiopathic ventricular fibrillation (IVF) is diagnosed in patients with sudden onset of ventricular fibrillation of unidentified origin. New diagnostic tools that can detect subtle abnormalities are needed to diagnose and treat patients with an underlying substrate.OBJECTIVE The purpose of this study was to explore echocardiographic deformation characteristics in IVF patients.METHODS Echocardiograms were analyzed with deformation imaging by 2-dimensional speckle tracking. Global and regional measurements of the left ventricle (LV) and right ventricle (RV) were performed. Regional LV deformation patterns were evaluated for the presence of postsystolic shortening. Regional RV deformation patterns were classified as type I (normal) or type II/III (abnormal).RESULTS In total, 47 IVF patients (mean age 45 years; left ventricular ejection fraction [LVEF] 56%) and 47 healthy controls (mean age 41 years; LVEF 60%) were included. IVF patients showed more global deformation abnormalities as indicated by lower LV global longitudinal strain (18.5% 6 2.6% vs 21.6% 6 1.8%; P ,.001) and higher LV mechanical dispersion (41 6 12 ms vs 26 6 6 ms; P ,.001). In addition, IVF patients showed more regional LV postsystolic shortening compared to healthy controls (50% vs 11%; P ,.001). Abnormal RV deformation patterns were observed in 16% of IVF patients and in none of the control subjects (P ,.001).CONCLUSION We were able to show both regional and global echocardiographic deformation abnormalities in IVF patients. This study provides evidence that localized myocardial disease is present in a subset of IVF patients.
Aims Stereotactic arrhythmia radiotherapy (STAR) is suggested as potentially effective and safe treatment for patients with therapy-refractory ventricular tachycardia (VT). However, the current prospective knowledge base and experience with STAR is limited. In this study we aimed to prospectively evaluate the efficacy and safety of STAR. Methods and results The StereoTactic Arrhythmia Radiotherapy in the Netherlands no.1 was a pre-post intervention study to prospectively evaluate efficacy and safety of STAR. In patients with therapy-refractory VT, the pro-arrhythmic region was treated with a 25 Gy single radiotherapy fraction. The main efficacy measure was a reduction in the number of treated VT-episodes by ≥50%, comparing the 12 months before and after treatment (or end of follow-up, excluding a 6-week blanking period). The study was deemed positive when ≥50% of patients would meet this criterion. Safety evaluation included left ventricular ejection fraction, pulmonary function, and adverse events. Six male patients with an ischaemic cardiomyopathy were enrolled, and median age was 73 years (range 54–83). Median left ventricular ejection fraction was 38% (range 24–52). The median planning target volume was 187 mL (range 93–372). Four (67%) patients completed the 12-month follow-up, and two patients died (not STAR related) during follow-up. The main efficacy measure of ≥50% reduction in treated VT-episodes at the end of follow-up was achieved in four patients (67%). The median number of treated VT-episodes was reduced by 87%. No reduction in left ventricular ejection fraction or pulmonary function was observed. No treatment related serious adverse events occurred. Conclusions STAR resulted in a ≥ 50% reduction in treated VT-episodes in 4/6 (67%) patients. No reduction in cardiac and pulmonary function nor treatment-related serious adverse events were observed during follow-up. Clinical trial registration Netherlands Trial Register—NL7510.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.