The frequency of DEA 1.1 expression in dogs in Portugal is high, and there is a potential risk of sensitization following transfusion with blood that is not typed or cross-matched. Breed-related frequencies may help predict DEA 1.1-positivity, but the best practice is to type and cross-match blood before transfusion.
BackgroundDuring the storage of packed red blood cells (pRBC), packed cell volume (PCV), bacterial contamination and percentage of haemolysis [percentage of free haemoglobin (HGB) in relation to the total HGB] are important quality parameters. Both PCV and haemolysis are indicators of the cellular integrity of stored units. There are no published experimental studies that evaluated these parameters during storage of feline pRBC using SAGM (adenine, dextrose, mannitol and sodium chloride) as the additive solution. The present study aims to (1) evaluate the quality of feline pRBCs stored in SAGM; (2) test for the semi-closed system’s suitability for use and risk of bacterial contamination; (3) establish the maximum storage time that may be appropriate to meet the criteria established by the United States Food and Drug Administration (US-FDA) guidelines for human blood banking; and (4) evaluate the need to calculate the percentage of haemolysis prior to the administration of units stored for more than 4 weeks.Four hundred eighty nine feline pRBC units were analyzed. Bacterial culture, PCV and percentage of haemolysis were determined within 6 h after processing (t0). One hundred and eighty units were re-tested for haemolysis and PCV after 29–35 days of storage (t1) and 118 units after 36–42 days (t2).ResultsBacterial contamination was not detected in any pRBC unit. Mean PCV at t0 was 52.25% (SD: ±5.27) and decreased significantly (p < 0.001) during storage to 48.15% (SD: ±3.79) at t1 and to 49.34% (SD: ±4.45) at t2. Mean percentage of haemolysis at t0 was 0.07% (SD: ±0.06) and increased significantly (p < 0.001) to 0.69% (SD: ±0.40) at t1 and to 0.81% (SD: ±0.47) at t2. In addition, 13.88% and 19.49% of pRBC units exceeded 1% haemolysis at t1 and t2, respectively.ConclusionsAccording to the US-FDA guidelines for human blood banking that recommend a maximum of 1% haemolysis, the results of this study show that all feline pRBC units with less than 24 h of shelf life have low levels of haemolysis. However, units preserved up to 28 days can only be administered if tested for haemolysis before use, since 13.88% units exceeded the 1% limit. The semi-closed system was considered safe for use as bacterial contamination was not detected in any pRBC unit.
Background -Hemolysis is an important quality parameter of packed red blood cells (pRBCs) that is used to assess the cellular integrity of stored blood units. According to human standards, hemolysis at the end of storage must not exceed 1%, as otherwise it may be responsible for decreased transfusion effectiveness and acute life-threatening reactions.Objectives -This prospective study was designed to evaluate the hemolysis of canine pRBCs stored in an additive solution containing adenine, dextrose, mannitol, and sodium chloride, and to assess its associations with storage time, duration of the collection process, collection disturbances, and with the final volume and PCV of the pRBCs units. Methods -One hundred eighty pRBCs units were collected from canine donors. Hemolysis of the pRBCs units was determined immediately after processing (t = 0). The units were then stored and retested (t = 1) either before administration (during weeks 2, 3, 4, 5, or 6 of storage) or at the end of the storage period (42 d) if not used. Results -Mean hemolysis at t = 0 was 0.09% (SD 0.06) and increased during storage, at a more pronounced rate from the 5th (mean values of 0.52%, SD 0.29) to the 6th week (1.2%, SD 0.72). Almost 51% of the units with 36-42 days of shelf-life showed more than 1% hemolysis. Disturbances in the collection process, the volume of the whole blood units, and the volume of stored pRBCs units or their PCV were not related to pRBCs hemolysis. Conclusions -According to human blood bank recommendations regarding acceptable hemolysis, canine pRBCs stored for more than 35 days should be tested to ensure <1% hemolysis prior to administration. (J Vet Emerg Crit Care 2018; 28(6): 512-517)
ObjectivesThe objective of this study was to document the prevalence of feline blood types in the Iberian Peninsula and to determine the potential risk of incompatibility-related transfusion reactions in unmatched transfusions and the potential risk of neonatal isoerythrolysis (NI) in kittens born to parents of unknown blood type.MethodsBlood samples were obtained from blood donors of the Animal Blood Bank (BSA-Banco de Sangue Animal). Blood typing was performed using a card method (RapidVet-H Feline Blood Typing; MDS).ResultsThe studied population comprised 1070 purebred and non-purebred cats from Portugal and Spain aged between 1 and 8 years. Overall, frequencies of blood types A and B were 96.5% and 3.5%, respectively. No AB cats were found. Based on these data, the potential risks of NI and transfusion reactions in unmatched transfusions were calculated to be 6.8% and 2.8%, respectively.Conclusions and relevanceUnlike previous studies, no type AB cats were found in this study. Although the calculated potential risks of transfusion reaction in unmatched transfusions and neonatal isoerythrolysis were low, blood typing prior to blood transfusion and blood typing of cats for breeding purposes are highly recommended.
Neste trabalho, descrevemos uma experiência simples e pedagógica para medir a energia livre de superfície (SFE) queé um tema dominante no ensino da Física, a nível de estudos de graduação e pós-graduação. A vantagem desta experiência baseia-se na simplicidade dos materiais utilizados, ou seja, produtos de baixo custo e não prejudiciais, comoágua, glicerol, etileno glicol e propanol, que oferecem uma boa oportunidade para discutir pedagogicamente conceitos básicos, mas relevantes sobre fenómenos de superfície. Como exemplo, medidas dê angulo de contacto foram utilizadas para estimar a SFE e a molhabilidade de diferentes superfícies sólidas, tais como o vidro e o politetrafluoretileno (PTFE, TeflonPalavras-chave: práticas pedagógicas, energia livre de superfície,ângulo de contacto.In this paper we describe a simple and pedagogical experiment to measure surface free energy (SFE), which is a mainstream subject to teach undergraduate and graduate level Physics science. Beyond this, the advantage of this work relies on the simplicity of the materials used, namely non-harmful and low cost products such as water, glycerol, ethylene glycol and propanol, offering a useful pedagogical opportunity to discuss basic but relevant concepts regarding surface science phenomena. As example, contact angle measurements were used to estimate SFE and the wetting behavior of distinct solid surfaces such as glass and polytetrafluoroethylene (PTFE, Teflon R ⃝ ).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.