A method is developed and validated for approximating continuous smooth distributions of finite strains in the ventricles from the deformations of magnetic resonance imaging (MRI) tissue tagging "tag lines" or "tag surfaces." Tag lines and intersections of orthogonal tag lines are determined using a semiautomated algorithm. Three-dimensional (3-D) reconstruction of the displacement field on tag surfaces is performed using two orthogonal sets of MRI images and employing spline surface interpolation. The 3-D regional ventricular wall strains are computed from an initial reference image to a deformed image in diastole or systole by defining a mapping or transformation of space between the two states. The resultant mapping is termed the measurement analysis solution and is defined by determining a set of coefficients for the approximating functions that best fit the measured tag surface displacements. Validation of the method is performed by simulating tag line or surface deformations with a finite element (FE) elasticity solution of the heart and incorporating the measured root-mean-square (rms) errors of tag line detection into the simulations. The FE-computed strains are compared with strains calculated by the proposed procedure. The average difference between two-dimensional (2-D) FE-computed strains and strains calculated by the measurement analysis was 0.022 +/- 0.009 or 14.2 +/- 3.6% of the average FE elasticity strain solution. The 3-D displacement reconstruction errors averaged 0.087 +/- 0.002 mm or 2.4 +/- 0.1% of the average FE solution, and 3-D strain fitting errors averaged 0.024 +/- 0.011 or 15.9 +/- 2.8% of the average 3-D FE elasticity solution. When the rms errors in tag line detection were included in the 2-D simulations, the agreement between FE solution and fitted solution was 24.7% for the 2-D simulations and 19.2% for the 3-D simulations. We conclude that the 3-D displacements of MRI tag lines may be reconstructed accurately; however, the strain solution magnifies the small errors in locating tag lines and reconstructing 3-D displacements.
There is evidence that appropriate footwear is an important factor in the prevention of foot pain in otherwise healthy people or foot ulcers in people with diabetes and peripheral neuropathy. A standard care for reducing forefoot plantar pressure is the utilization of orthotic devices such as total contact inserts (TCI) with therapeutic footwear. Most neuropathic ulcers occur under the metatarsal heads, and foot deformity combined with high localized plantar pressure, appear to be the most significant factors contributing to these ulcers. In this study, patient-specific finite element models of the second ray of the foot were developed to study the influence of TCI design on peak plantar pressure (PPP) under the metatarsal heads. A typical full contact insert was modified based on the results of finite element analyses, by inserting 4 mm diameter cylindrical plugs of softer material in the regions of high pressure. Validation of the numerical model was addressed by comparing the numerical results obtained by the finite element method with measured pressure distribution in the region of the metatarsal heads for a shoe and TCI condition. Two subjects, one with a history of forefoot pain and one with diabetes and peripheral neuropathy, were tested in the laboratory while wearing therapeutic shoes and customized inserts. The study showed that customized inserts with softer plugs distributed throughout the regions of high plantar pressure reduced the PPP over that of the TCI alone. This supports the outcome as predicted by the numerical model, without causing edge effects as reported by other investigators using different plug designs, and provides a greater degree of flexibility for customizing orthotic devices than current practice allows.
The primary objective of conservative care for the diabetic foot is to protect the foot from excessive pressures. Pressure reduction and redistribution may be achieved by designing and fabricating orthotic devices based on foot structure, tissue mechanics, and
The definition, essential properties and formulation of hierarchic models for laminated plates and shells are presented. The hierarchic models satisfy three essential requirements: approximability; asymptotic consistency, and optimality of convergence rate. Aspects of implementation are discussed and the performance characteristics are illustrated by examples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.