CHF promotes inducibility of sustained atrial tachycardia. Based on the mode of tachycardia induction, responses to pacing and calcium antagonists, and presence of DADs, atrial tachycardia in this CHF model has a mechanism most consistent with DAD-induced triggered activity resulting from intracellular calcium overload.
Acute complications resulting from permanent pacemaker implantation are well known and include perforation of the right atrium or right ventricle. Recently, several reports have described the occurrence of perforation and pericarditis as late complications following pacemaker implantation. These complications may occur days to weeks following uncomplicated pacemaker implantation and may lead to death if they are not recognized early. Five patients with late complications caused by active-fixation leads are reported and the clinical features of their presentation and management are reviewed. Late perforation of the right atrium or right ventricle is an uncommon complication after pacemaker implantation but should be suspected by the general cardiologist in a patient who has a device implanted within a week to several months prior to the development of chest pain.
Background-Left ventricular assist devices (LVADs) are increasingly used as a bridge to cardiac transplantation or as destination therapy. Patients with LVADs are at high risk for ventricular arrhythmias. This study describes ventricular arrhythmia characteristics and ablation in patients implanted with a Heart Mate II device. Methods and Results-All patients with a Heart Mate II device who underwent ventricular arrhythmia catheter ablation at 9 tertiary centers were included. Thirty-four patients (30 male, age 58±10 years) underwent 39 ablation procedures. The underlying cardiomyopathy pathogenesis was ischemic in 21 and nonischemic in 13 patients with a mean left ventricular ejection fraction of 17%±5% before LVAD implantation. One hundred and ten ventricular tachycardias (VTs; cycle lengths, 230-740 ms, arrhythmic storm n=28) and 2 ventricular fibrillation triggers were targeted (25 transseptal, 14 retrograde aortic approaches). Nine patients required VT ablation <1 month after LVAD implantation because of intractable VT. Only 10/110 (9%) of the targeted VTs were related to the Heart Mate II cannula. During follow-up, 7 patients were transplanted and 10 died. Of the remaining 17 patients, 13 were arrhythmia-free at 25±15 months. In 1 patient with VT recurrence, change of turbine speed from 9400 to 9000 rpm extinguished VT. Conclusions-Catheter ablation of VT among LVAD recipients is feasible and reasonably safe even soon after LVAD implantation. Intrinsic myocardial scar, rather than the apical cannula, seems to be the dominant substrate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.