One hundred sixty horses were anesthetized with xylazine, guaifenesin, thiamylal, and halothane for elective soft tissue and orthopedic procedures. Horses were randomly assigned to one of four groups. Group 1 (n = 40): Horses positioned in lateral (LRG1; n = 20) or dorsal (DRG1; n = 20) recumbency breathed spontaneously throughout anesthesia. Group 2 (n = 40): Intermittent positive pressure ventilation (IPPV) was instituted throughout anesthesia in horses positioned in lateral (LRG2; n = 20) or dorsal (DRG2; n = 20) recumbency. Group 3 (n = 40): Horses positioned in lateral (LRG3; n = 20) or dorsal (DRG3; n = 20) recumbency breathed spontaneously for the first half of anesthesia and intermittent positive pressure ventilation was instituted for the second half of anesthesia. Group 4 (n = 40): Intermittent positive pressure ventilation was instituted for the first half of anesthesia in horses positioned in lateral (LRG4; n = 20) or dorsal (DRG4; n = 20) recumbency. Spontaneous ventilation (SV) occured for the second half of anesthesia. The mean time of anesthesia was not significantly different within or between groups. The mean time of SV and IPPV was not significantly different in groups 3 and 4. Variables analyzed included pH, PaCO2, PaO2, and P(A-a)O2 (calculated). Spontaneous ventilation resulted in significantly higher PaCO2 and P(A-a)O2 values and significantly lower PaO2 values in LRG1 and DRG1 horses compared with LRG2 and DRG2 horses. Intermittent positive pressure ventilation resulted in normocarbia and significantly lower P(A-a)O2 values in LRG2 and DRG2 horses. In LRG2 the PaO2 values significantly increased from 20 minutes after induction to the end of anesthesia. The PaO2 and P(A-a)O2 values were not significantly different from the beginning of anesthesia after IPPV in DRG2 or DRG3. The PaO2 values significantly decreased and the P(A-a)O2 values significantly increased after return to SV in horses in LRG4 and DRG4. The PaO2 values were lowest and the P(A-a)O2 values were highest in all horses positioned in dorsal recumbency compared with lateral recumbency and in SV horses compared with IPPV horses. The pH changes paralleled the changes in PaCO2. Blood gas values during right versus left lateral recumbency in all groups were also evaluated. The PaO2 values were significantly lower and the P(A-a)O2 values were significantly higher during SV in horses positioned in left lateral (LRLG1) compared with right lateral (LRRG1) recumbency.(ABSTRACT TRUNCATED AT 400 WORDS)
Safe and effective anesthesia of dogs and cats rely on preanesthetic patient assessment and preparation. Patients should be premedicated with drugs that provide sedation and analgesia prior to anesthetic induction with drugs that allow endotracheal intubation. Maintenance is typically with a volatile anesthetic such as isoflurane or sevoflurane delivered via an endotracheal tube. In addition, local anesthetic nerve blocks; epidural administration of opioids; and constant rate infusions of lidocaine, ketamine, and opioids are useful to enhance analgesia. Cardiovascular, respiratory, and central nervous system functions are continuously monitored so that anesthetic depth can be modified as needed. Emergency drugs and equipment, as well as an action plan for their use, should be available throughout the perianesthetic period. Additionally, intravenous access and crystalloid or colloids are administered to maintain circulating blood volume. Someone trained in the detection of recovery abnormalities should monitor patients throughout recovery. Postoperatively attention is given to body temperature, level of sedation, and appropriate analgesia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.