Ergonomic problems of surgical lighting systems have been indicated by surgeons. However, the underlying causes are not clear. The aim of this study is to assess the problems in detail. Luminaire use during 46 h of surgery was observed and quantified. Furthermore, a questionnaire on perceived illumination of and usability problems with surgical luminaires was issued among OR-staff in 13 hospitals. The results showed that every 7.5 min a luminaire action (LA) takes place, intended to reposition the luminaire. Of these LAs, 74% was performed by surgeons and residents. For 64% of these LAs the surgical tasks of OR-staff were interrupted. The amount of LAs to obtain a well-lit wound, illumination level, shadows, and illumination of deep wounds were most frequently indicated lighting aspects needing improvement. Different kinematic aspects of the pendant system of the lights that influence usability were also mentioned: high forces for repositioning, ease of focusing and aiming, ease of moving, collisions of the luminaire, entangling of pendant arms, and maneuverability. Based on these results, conclusions regarding to improvement of surgical lighting systems are formulated. Focus for improvements should be on minimizing the need for repositioning the luminaire, and on minimizing the effort for repositioning.
Ergonomic problems of surgical lighting systems have been indicated by surgeons; however, the underlying causes are not clear. The aim of this study is to assess the problems in detail. Luminaire use during 46 hours of surgery was observed and quantified. Furthermore, a questionnaire on perceived illumination of and usability problems with surgical luminaires was issued among OR-staff in 13 hospitals. The results showed that every 7.5 minutes a luminaire action (LA) takes place, intended to reposition the luminaire. Of these LAs, 74% were performed by surgeons and residents. For 64% of these LAs the surgical tasks of the OR-staff were interrupted. The amount of LAs to obtain a well-lit wound, the illumination level, shadows, and the illumination of deep wounds were most frequently indicated lighting aspects needing improvement. Different kinematic aspects of the pendant system of the lights that influence usability were also mentioned: High forces for repositioning, ease of focusing and aiming, ease of moving, collisions of the luminaire, entangling of pendant arms, and maneuverability. Based on these results conclusions regarding the improvement of surgical lighting systems are formulated. Focus for improvements should be on minimizing the need for repositioning the luminaire, and on minimizing the effort for repositioning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.