Here, we report a new surgical technique designed to increase filtration volume and reduce intraocular pressure (IOP) in glaucoma and its one-year outcome. Two tubes were created from a single Baerveldt glaucoma implant (BI) by folding the tube in a U-shape and incising only the outer edge of the stretched loop tip. The tubes were placed into the vitreous cavity via the pars plana through a long scleral tunnel, without a scleral valve or graft patch. Twenty eyes of 18 patients with neovascular glaucoma were included. This technique was performed in 10 eyes of 10 patients (double group), and outcomes were compared to 10 eyes of eight patients in which a single tube BI was inserted (single group). The primary outcome measures included IOP, supplemental medical therapy score (SMTS), and intraoperative and postoperative complications before and after surgery at 12 months. The mean IOP (SMTS) were 32.0 ± 11.33 mmHg (4.1) in the double group and 29.7 ± 6.31 mmHg (5.7) in the single group, preoperatively reduced to 11.8 ± 2.70 mmHg (0.2) (63% reduction, p < 0.004) and 14.2 ± 4.05 mmHg (1.1) (52% reduction, p < 0.002) after 12 months, respectively. SMTS showed 95% (p = 0.005) and 89% (p = 0.005) reductions, respectively. Although there was no significant difference in IOP between the two groups at 12 months (p = 0.16), there were significant differences in the SMTS between the two groups before, and 6 and 12 months after, surgery (p = 0.01, 0.04 and 0.04, respectively). A reduction in the SMTS suggests that increasing filtration volume by placing two tubes has the potential to further reduce IOP as compared with a single tube.
Background We previously reported a novel technique using an elastic silicone bowl, which was handmade from a phaco test chamber, to salvage dislocated lenses and perform phacoemulsification and aspiration (PEA) on the bowl. However, creating the bowl was challenging. Methods A factory-made elastic silicone sheet (ESS), a ready-to-use alternative for the posterior capsule of the lens, was prepared. We used this sheet to salvage and support the dislocated/subluxated lenses in 11 eyes of nine patients. Results We could use a sheet immediately after we opened the package. In all the cases, we could insert a sheet beneath the lens and PEA performed at the center of the operative field. There was only one incident where the lens could not be placed onto the disc at the first attempt, but the lens was eventually salvaged. There was no risk of rupture during PEA, and the ESS could be removed completely without any complications. Conclusion The factory-made ESS described here can be used for salvaging dislocated/subluxated lenses and safely performing PEA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.