Background
Thrombotic thrombocytopenic purpura (TTP) is a rare but potentially fatal disorder caused by ADAMTS13 (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13) deficiency. Prompt identification/exclusion of TTP can thus be facilitated by rapid ADAMTS13 testing. The most commonly utilized (enzyme‐linked immunosorbent assay [ELISA]–based) assay takes several hours to perform and so does not generally permit rapid testing.
Objectives
To evaluate the utility of a new automated test for ADAMTS13 activity, the HemosIL AcuStar ADAMTS13 Activity assay, based on chemiluminescence and able to be performed on an ACL AcuStar instrument within 33 minutes.
Patients/Methods
This multicenter (n = 8) assessment included testing of more than 700 test samples, with similar numbers of prospective (n = 348) and retrospective (n = 385) samples. The main comparator was the Technozym ADAMTS13 Activity ELISA. We also assessed comparative performance for detection of ADAMTS13 inhibitors using a Bethesda assay.
Results
Overall, the chemiluminescent assay yielded similar results to the comparator ELISA, albeit with slight negative bias. ADAMTS13 inhibitor detection was also comparable, albeit with slight positive bias with the AcuStar assay. Assay precision was similar with both assays, and we also verified assay normal reference ranges.
Conclusions
The HemosIL AcuStar ADAMTS13 Activity assay provided results rapidly, which were largely comparable with the Technozym ADAMTS13 Activity ELISA assay, albeit lower on average. Conversely, inhibitor levels tended to be identified at a higher level on average. Thus, the HemosIL AcuStar ADAMTS13 Activity assay provides a fast and accurate means to quantitate plasma levels of ADAMTS13 for TTP/ADAMTS13 identification/exclusion, and potentially also for other applications.
The Jk(a−b−) phenotype is rare. Individuals with the Jk null phenotype are at risk of developing anti-Jk3. Anti-Jk3 can cause both acute and delayed haemolytic transfusion reactions, as well as possible haemolytic disease of the fetus and newborn. The presence of anti-
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.