CAV results in diffuse concentric intimal thickening of the epicardial vessels affecting both the proximal and distal vessels as well as the microcirculation.3 This progressive luminal narrowing and loss of vasodilatory capacity culminates in myocardial ischemia and contractile dysfunction. Immunemediated injury plays a significant role in the development of epicardial vessel stenosis in addition to traditional risk factors. 4 Clinical symptoms such as angina are typically absent in cases of CAV because of allograft denervation, and therefore annual screening is used in most centers.Recent guidelines recommend periodic invasive coronary angiography for at least the first 3 to 5 years after transplantation. 5 However, this is inconvenient and adds risk. Hence, many centers have elected to monitor patients with noninvasive testing, but this strategy may be suboptimal because of the lower sensitivity for the detection of early CAV. 6,7 Rubidium-82 (Rb-82) positron emission tomography (PET) myocardial perfusion imaging is a noninvasive imaging modality that has the ability to quantify myocardial blood flow (MBF) 8 and has been shown to have prognostic value in patients being assessed for ischemia.9-11 This technique may facilitate earlier detection of CAV and thus may have prognostic value in HT patients. The objective of this study was to evaluate the prognostic value of Rb-82 PET in patients with a history of HT.Background-Cardiac allograft vasculopathy is a key prognostic determinant after heart transplant. Detection and risk stratification of patients with cardiac allograft vasculopathy are problematic. Positron emission tomography using rubidium-82 allows quantification of absolute myocardial blood flow and may have utility for risk stratification in this population. Methods and Results-Patients with a history of heart transplant undergoing dipyridamole rubidium-82 positron emission tomography were prospectively enrolled. Myocardial perfusion and left ventricular ejection fraction were recorded. Absolute flow quantification at rest and after dipyridamole stress as well as the ratio of mean global flow at stress and at rest, termed myocardial flow reserve, were calculated. Patients were followed for all-cause death, acute coronary syndrome, and heart failure hospitalization. A total of 140 patients (81% men; median age, 62 years; median follow-up, 18.2 months) were included. There were 14 events during follow-up (9 deaths, 1 acute coronary syndrome, and 4 heart failure admissions). In addition to baseline clinical variables (estimated glomerular filtration rate, previously documented cardiac allograft vasculopathy), relative perfusion defects, mean myocardial flow reserve, and mean stress myocardial blood flow were significant predictors of adverse outcome. Conclusions-Abnormalities on rubidium-82 positron emission tomography were predictors of adverse events in heart transplant patients. Larger prospective studies are required to confirm these findings. (Circ Cardiovasc Imaging. 2014;7:930-937.)
Respiratory motion can induce artifacts in cardiac PET/CT because of the misregistration of the CT attenuation map and emission data. Some solutions to the respiratory motion problem use 4-dimensional CT, but this increases patient radiation exposure. Realignment of 3-dimensional CT and PET images can remove apparent uptake defects caused by mispositioning of the PET emission data into the lung regions on the CT scan. This realignment is typically done as part of regular clinical quality assurance. We evaluated a method to improve on this standard approach, without increasing the radiation exposure to the patient, by acquiring a respiration-gated PET scan and separately aligning the 3-dimensional CT scan to each phase of the PET study. Methods: Three hundred ten clinical PET perfusion scans ( 82 Rb [n 5 187] and 13 N-ammonia [n 5 123]) were retrospectively assessed. Studies were respiration-gated, and motion was measured between inspiration and expiration phases. Those studies with motion $ 8 mm were evaluated for significant differences between inspiration and expiration. Studies with significant differences were reprocessed with the phase-alignment approach. The observed motion with 82 Rb and 13 N-ammonia for rest and stress imaging was also compared. Results: Twentythree scans (7.41%) had motion $ 8 mm, and 9 of these had significant differences between inspiration and expiration, suggesting the presence of respiratory artifacts. Phase-aligned respiratory motion compensation reduced this difference in 8 of 9 cases (89%). No significant differences were observed between 82 Rb and 13 N-ammonia, and motion during stress imaging was correlated with motion at rest (r 5 0.61, P , 0.001). Conclusion: Phase-aligned correction improves the consistency of PET/CT perfusion images by reducing discrepancies caused by respiratory motion. This new approach to CT-based attenuation correction has no additional patient radiation exposure and may improve the specificity of PET perfusion imaging. Accurat e attenuation correction (AC) is a major clinical advantage of PET, compared with SPECT, and has been well accepted when the attenuation map is formed using data from radioactive transmission sources. However, respiratory motion can induce artifacts in cardiac PET/CT because of misregistration of the CT attenuation map and emission data. Misregistration has been shown to occur in up to 40% of clinical cardiac PET/CT studies (1). The most common artifact is an apparent decrease in uptake in the anterior or lateral wall due to a mispositioning of the activity from the heart into the low-attenuating tissues of the lungs. Many studies have examined the effect of this misalignment and found that motion of 6-8 mm produces mild to moderate errors, and motion .8 mm leads to severe errors that may affect clinical interpretation (1,2). Several approaches have been suggested to reduce the impact of this problem including simple realignment of the CT scan and the PET data (2,3), slow CT scans (4), and methods that estimate the motion from r...
UCP3 (uncoupling protein-3) mitigates mitochondrial ROS (reactive oxygen species) production, but the mechanisms are poorly understood. Previous studies have also examined UCP3 effects, including decreased ROS production, during metabolic states when fatty acid oxidation is high (e.g. a fasting state). However, the role of UCP3 when carbohydrate oxidation is high (e.g. fed state) has remained largely unexplored. In the present study, we show that mitochondrial-bound HK (hexokinase) II curtails oxidative stress and enhances aerobic metabolism of glucose in the fed state in a UCP3-dependent manner. Genetic knockout or inhibition of UCP3 significantly decreased mitochondrial-bound HKII. Furthermore, UCP3 was required for the HKII-mediated decrease in mitochondrial ROS emission. Intriguingly, the UCP3-mediated modulation of mitochondria-associated HKII was only observed in cells cultured under high-glucose conditions. UCP3 was required to maintain high rates of aerobic metabolism in high-glucose-treated cells and in muscle of fed mice. Deficiency in UCP3 resulted in a metabolic shift that favoured anaerobic glycolytic metabolism, increased glucose uptake and increased sensitivity to oxidative challenge. PET (positron emission tomography) of [18F]fluoro-deoxyglucose uptake confirmed these findings in UCP3-knockout and wild-type mice. Collectively, our findings link the anti-oxidative and metabolic functions of UCP3 through a surprising molecular connection with mitochondrial-bound HKII.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.