Seprafilm antiadhesions membrane appears effective in reducing the severity of postoperative adhesions after major abdominal surgery, although the incidence of adhesions was not diminished. The authors recommend using Seprafilm when relaparotomy or second-look intervention is planned. Long-term studies are needed to assess the cost-effectiveness and value of Seprafilm in preventing bowel obstruction, chronic abdominal pain, and infertility.
Summary
Background
Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes.
Methods
For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813.
Findings
Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79).
Interpretation
In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws.
Funding
National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
The DASH and Constant-Murley are valid instruments for evaluating outcome in patients with a humeral shaft fracture. Reliability was only shown for the DASH, making this the preferred instrument. The observed MIC and SDC values provide a basis for sample size calculations for future research.
Objective:
To describe the distribution of femoral neck shortening after internal fixation and to determine whether shortening is associated with inferior hip function at 24 months after a hip fracture in patients 50 years of age or older.
Design:
Retrospective cohort study.
Setting:
A secondary analysis of data from 81 clinical centers included in the Fixation using Alternative Implants for the Treatment of Hip Fractures (FAITH) trial.
Participants:
Three hundred fifty patients, 50 years of age or older, who had an isolated femoral neck fracture and underwent timely operative fixation of the fracture.
Intervention:
Femoral neck shortening was measured as a categorical variable and classified into one of the following groups, as determined by the Central Adjudication Committee: no shortening, mild shortening (≤5 mm), moderate shortening (6–10 mm), or severe shortening (>10 mm).
Main Outcome Measurement:
The primary outcome for the current analysis was hip function, as measured by the Western Ontario & McMaster Universities Osteoarthritis Index questionnaire, at 24 months after injury.
Results:
Two-thirds of patients had no or mild shortening (≤5 mm), whereas one-third of patients had moderate or severe shortening (>5 mm). After adjusting for surgical treatment, a greater amount of femoral neck shortening was found to be associated with poorer hip function (P < 0.01).
Conclusions:
We found that increasing femoral neck shortening was associated with inferior hip function. Although internal fixation often results in successful union, patients who heal in a shortened position report poorer functional outcomes.
Level of Evidence:
Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.