High-energy ion beams are successfully used in cancer therapy and precisely deliver high doses of ionizing radiation to small deep-seated target volumes. A similar noninvasive treatment modality for cardiac arrhythmias was tested here. This study used high-energy carbon ions for ablation of cardiac tissue in pigs. Doses of 25, 40, and 55 Gy were applied in forced-breath-hold to the atrioventricular junction, left atrial pulmonary vein junction, and freewall left ventricle of intact animals. Procedural success was tracked by (1.) in-beam positron-emission tomography (PET) imaging; (2.) intracardiac voltage mapping with visible lesion on ultrasound; (3.) lesion outcomes in pathohistolgy. High doses (40–55 Gy) caused slowing and interruption of cardiac impulse propagation. Target fibrosis was the main mediator of the ablation effect. In irradiated tissue, apoptosis was present after 3, but not 6 months. Our study shows feasibility to use high-energy ion beams for creation of cardiac lesions that chronically interrupt cardiac conduction.
The authors presented a simple simulation model for therapeutical (4)He beams which they introduced in TRiP98, and which is validated experimentally by means of physical and biological dosimetries. Thus, it is now possible to perform detailed treatment planning studies with (4)He beams, either exclusively or in combination with other ion modalities.
This investigation focused on the characterization of the lateral dose fall-off following the irradiation of the target with photons, protons and carbon ions. A water phantom was irradiated with a rectangular field using photons, passively delivered protons as well as scanned protons and carbon ions. The lateral dose profile in the depth of the maximum dose was measured using an ion chamber, a diamond detector and thermoluminescence detectors TLD-600 and TLD-700. The yield of thermal neutrons was estimated for all radiation types while their complete spectrum was measured with bubble detectors during the irradiation with photons. The peripheral dose delivered by photons is significantly higher compared to both protons and carbon ions and exceeds the latter by up to two orders of magnitude at distances greater than 50 mm from the field. The comparison of passive and active delivery techniques for protons shows that, for the chosen rectangular target shape, the former has a sharper penumbra whereas the latter has a lower dose in the far-out-of-field region. When comparing scanning treatments, carbon ions present a sharper dose fall-off than protons close to the target but increasing peripheral dose with increasing incident energy. For photon irradiation, the contribution to the out-of-field dose of photoneutrons appears to be of the same order of magnitude as the scattered primary beam. Charged particles show a clear supremacy over x-rays in achieving a higher dose conformality around the target and in sparing the healthy tissue from unnecessary radiation exposure. The out-of-field dose for x-rays increases with increasing beam energy because of the production of biologically harmful neutrons.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.