We present an extended optical characterization of an adaptive microfluidic silicone-membrane lens at a wavelength of 633 nm, respectively 660 nm. Two different membrane variations; one with a homogeneous membrane thickness, and one with a shaped cross section, have been realized. This paper includes the theoretical predictions of the optical performance via FEM simulation and ray tracing, and a subsequent orientation dependent experimental analysis of the lens quality which is measured with an MTF setup and a Mach-Zehnder interferometer. The influence of the fabrication process on the optical performance is also characterized by the membrane deformation in the non-deflected state. The lens with the homogeneous membrane of 5 mm in diameter and an aperture of 2.5 mm indicates an almost orientation independent image quality of 117 linepairs/mm at a contrast of 50%. The shaped membrane lenses show a minimum wave front error of WFE(RMS) = 24 nm, and the lenses with a planar membrane of WFE(RMS) = 31 nm at an aperture of 2.125 mm.
The role of the vocal tract for phonation at very high soprano fundamental frequencies (F0s) is not yet understood in detail. In this investigation, two experiments were carried out with a single professional high soprano subject. First, using two dimensional (2D) dynamic real-time magnetic resonance imaging (MRI) (24 fps) midsagittal and coronal vocal tract shapes were analyzed while the subject sang a scale from Bb5 (932 Hz) to G6 (1568 Hz). In a second experiment, volumetric vocal tract MRI data were recorded from sustained phonations (13 s) for the pitches C6 (1047 Hz) and G6 (1568 Hz). Formant frequencies were measured in physical models created by 3D printing, and calculated from area functions obtained from the 3D vocal tract shapes. The data showed that there were only minor modifications of the vocal tract shape. These changes involved a decrease of the piriform sinus as well as small changes of tongue position. Formant frequencies did not exhibit major differences between C6 and G6 for F1 and F3, respectively. Only F2 was slightly raised for G6. For G6, however, F2 is not excited by any voice source partial. Therefore, this investigation was not able to confirm that the analyzed professional soprano subject adjusted formants to voice source partials for the analyzed F0s.
We present the fabrication process of a fluidic membrane lens system with an integrated piezoelectric pumping actuator. The optical unit and the pumping unit are fabricated through casting using a hot embossing machine. Two different systems, one with a homogeneous membrane thickness, and one with an inhomogeneous membrane thickness distribution, are manufactured. The influence of the volume shrinkage of the silicone during curing on the membrane shape and on the focal length is analyzed. The assembled system achieves a focal length between +52.4 mm and −70.9 mm at a piezovoltage of ±40 V. The full-scale response time of the system is below 24 ms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.