This study examines the reproducibility of gastro-intestinal blood flow measurements in the superior mesenteric artery (SMA) both before and immediately after exercise with Doppler ultrasound measurements. Twelve well-trained males (mean +/- SD: age 25.9 +/- 3.8 yr; VO2max 4.8 +/- 0.91 x min(-1)) were measured twice (trial 1 and 2) with a 1 week interval before and immediately after 1 hr cycling at 70% VO2max. Duplex scanning was performed with the athletes in supine position immediately after transition from a chair (before exercise) or bicycle (after exercise). The variability of three measurements before exercise was studied within both trials (short-term reproducibility) and the mean pre-exercise values were compared between the trials (long-term reproducibility). In addition, post-exercise measurements were compared in the same way. Reproducibility was tested using the coefficient of variation and Cronbach's alpha. Mean pre-exercise blood flow was 424 +/- 66 ml/min (n = 12) in trial 1 and 375 +/- 38 ml/min (n = 11) in trial 2. Immediately after exercise blood flow had decreased by 49% to 214 +/- 36 ml/min (p <0.01) in trial 1 and by 38% to 234 +/- 36 ml/min (p < 0.01) in trial 2. Blood flow before and after exercise was not significantly different between trials (paired t-test) and therefore reproducible at the group level. Before exercise a good to fair reproducibility was observed both at the short-term (Cronbach's alpha: 0.88 in trial 1, 0.73 in trial 2, n = 11), and at the long-term (alpha = 0.80, n= 11). In contrast, long-term reproducibility immediately after exercise was poor (alpha = -0.99, n = 8 and alpha = 0.36, n = 7 after the first and second cycling period, respectively). In conclusion, duplex scanning of SMA after a sitting-supine transition in well-trained subjects is not a reproducible method at the individual level for intestinal blood flow measurements immediately after exercise.
, an incorrect unit has been printed in table 2 ªSaliva analysisº on page 129: The total protein concentration is given in mg/ml (rather than mg/ml). We apologize for this mistake..
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.