Running-related injuries remain problematic among recreational runners. We evaluated the association between having sustained a recent running-related injury and speed, and the strike index (a measure of footstrike pattern, SI) and spatiotemporal parameters of running. Forty-four previously injured and 46 previously uninjured runners underwent treadmill running at 80%, 90%, 100%, 110%, and 120% of their preferred running speed. Participants wore a pressure insole device to measure SI, temporal parameters, and stride length (S length) and stride frequency (Sfrequency) over 2-min intervals. Coefficient of variation and detrended fluctuation analysis provided information on stride-to-stride variability and correlative patterns. Linear mixed models were used to compare differences between groups and changes with speed. Previously injured runners displayed significantly higher stride-to-stride correlations of SI than controls (P = 0.046). As speed increased, SI, contact time (T contact), stride time (Tstride), and duty factor (DF) decreased (P < 0.001), whereas flight time (Tflight), Slength, and Sfrequency increased (P < 0.001). Stride-to-stride variability decreased significantly for SI, Tcontact, Tflight, and DF (P ≤ 0.005), as did correlative patterns for Tcontact, Tstride, DF, Slength, and Sfrequency (P ≤ 0.044). Previous runningrelated injury was associated with less stride-to-stride randomness of footstrike pattern. Overall, runners became more pronounced rearfoot strikers as running speed increased.
The aim of this study was to determine if runners who use concomitantly different pairs of running shoes are at a lower risk of running-related injury (RRI). Recreational runners (n = 264) participated in this 22-week prospective follow-up and reported all information about their running session characteristics, other sport participation and injuries on a dedicated Internet platform. A RRI was defined as a physical pain or complaint located at the lower limbs or lower back region, sustained during or as a result of running practice and impeding planned running activity for at least 1 day. One-third of the participants (n = 87) experienced at least one RRI during the observation period. The adjusted Cox regression analysis revealed that the parallel use of more than one pair of running shoes was a protective factor [hazard ratio (HR) = 0.614; 95% confidence interval (CI) = 0.389-0.969], while previous injury was a risk factor (HR = 1.722; 95%CI = 1.114-2.661). Additionally, increased mean session distance (km; HR = 0.795; 95%CI = 0.725-0.872) and increased weekly volume of other sports (h/week; HR = 0.848; 95%CI = 0.732-0.982) were associated with lower RRI risk. Multiple shoe use and participation in other sports are strategies potentially leading to a variation of the load applied to the musculoskeletal system. They could be advised to recreational runners to prevent RRI.
Running biomechanics has received increasing interest in recent literature on running-related injuries, calling for new, portable methods for large-scale measurements. Our aims were to define running strike pattern based on output of a new pressure-sensitive measurement device, the Runalyser, and to test its validity regarding temporal parameters describing running gait. Furthermore, reliability of the Runalyser measurements was evaluated, as well as its ability to discriminate different running styles. Thirty-one healthy participants (30.3 ± 7.4 years, 1.78 ± 0.10 m and 74.1 ± 12.1 kg) were involved in the different study parts. Eleven participants were instructed to use a rearfoot (RFS), midfoot (MFS) and forefoot (FFS) strike pattern while running on a treadmill. Strike pattern was subsequently defined using a linear regression (R(2)=0.89) between foot strike angle, as determined by motion analysis (1000 Hz), and strike index (SI, point of contact on the foot sole, as a percentage of foot sole length), as measured by the Runalyser. MFS was defined by the 95% confidence interval of the intercept (SI=43.9-49.1%). High agreement (overall mean difference 1.2%) was found between stance time, flight time, stride time and duty factor as determined by the Runalyser and a force-measuring treadmill (n=16 participants). Measurements of the two devices were highly correlated (R ≥ 0.80) and not significantly different. Test-retest intra-class correlation coefficients for all parameters were ≥ 0.94 (n=14 participants). Significant differences (p<0.05) between FFS, RFS and habitual running were detected regarding SI, stance time and stride time (n=24 participants). The Runalyser is suitable for, and easily applicable in large-scale studies on running biomechanics.
Pressure-sensitive measuring devices have been identified as appropriate tools for measuring an array of parameters during running. It is unclear which biomechanical characteristics relate to running-related injury (RRI) and which data-processing techniques are most promising to detect this relationship. This systematic review aims to identify pertinent methodologies and characteristics measured using plantar pressure devices, and to summarise their associations with RRI. PubMed, Embase, CINAHL, ScienceDirect and Scopus were searched up until March 2015. Retrospective and prospective, biomechanical studies on running using any kind of pressure-sensitive device with RRI as an outcome were included. All studies involving regular or recreational runners were considered. The study quality was assessed and the measured parameters were summarised. One low quality, two moderate quality and five high quality studies were included. Five different subdivisions of plantar area were identified, as well as five instants and four phases of measurement during foot-ground contact. Overall many parameters were collated and subdivided as plantar pressure and force, plantar pressure and force location, contact area, timing and stride parameters. Differences between the injured and control group were found for mediolateral and anteroposterior displacement of force, contact area, velocity of force displacement, relative force-time integral, mediolateral force ratio, time to peak force and inter-stride correlative patterns. However, no consistent results were found between studies and no biomechanical risk patterns were apparent. Additionally, conflicting findings were reported for peak force in three studies. Based on these observations, we provide suggestions for improved methodology measurement of pertinent parameters for future studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.