Screening for colonization with methicillin-resistant Staphylococcus aureus (MRSA) is a key aspect of infection control to limit the nosocomial spread of this organism. Current methods for the detection of MRSA in clinical microbiology laboratories, including molecularly based techniques, require a culture step and the isolation of pure colonies that result in a minimum of 20 to 24 h until a result is known. We describe a qualitative in vitro diagnostic test for the rapid detection of MRSA directly from nasal swab specimens (IDI-MRSA; Infectio Diagnostic, Inc., Sainte-Foy, Québec, Canada), based upon a real-time PCR and direct detection of MRSA via amplicon hybridization with a fluorogenic target-specific molecular beacon probe. Samples from 288 patients were analyzed for the presence of MRSA with the IDI-MRSA assay, compared to detection by either direct plating or enrichment broth selective culture methods. The diagnostic values for this MRSA screening method were 91.7% sensitivity, 93.5% specificity, 82.5% positive predictive value, and 97.1% negative predictive value when compared to culture-based methods. The time from the start of processing of specimen to result was approximately 1.5 h. In our hands, the IDI-MRSA assay is a sensitive and specific test for detection of nasal colonization with MRSA and providing for same-day results, allowing more efficient and effective use of infection control resources to control MRSA in health care facilities.
We evaluated the Prodesse ProFlu-1 real-time reverse transcription-PCR multiplex assay with the SmartCycler instrument for the detection of human respiratory syncytial virus (RSV) and influenza A and B viruses in comparison to conventional cell culture and antigen immunoassays with the BD Directigen A؉B and Binax NOW RSV assays over two successive respiratory virus seasons. Ninety-two percent of the 361 specimens tested were nasopharyngeal aspirates obtained from individual patients, of which 119 were positive for RSV and 59 were positive for influenza virus. The median age of the patients whose specimens were positive for RSV and influenza virus were 6.3 months and 42.4 years, respectively. The specificity of all of the methods tested was >99%, and the individual sensitivities of NOW RSV, RSV culture, Directigen A؉B, influenza virus culture, and the Proflu-1 PCR for influenza/RSV were 82% (95% confidence interval [CI], 73 to 88), 57% (95% CI, 44 to 69), 59% (95% CI, 44 to 72), 54% (95% CI, 38 to 69), and 98% (95% CI, 93 to 100)/95% (95% CI, 85 to 99), respectively. In a clinical setting where viral isolation is performed to confirm rapid antigen immunoassay results for these common respiratory viruses, one-step real-time reverse transcriptase PCR testing can be a more sensitive and timely confirmatory method.Human respiratory syncytial virus (RSV) and influenza A and B viruses are respiratory pathogens associated with substantial morbidity and mortality annually (43). Virtually all children become infected with RSV within 2 years after birth, and 1% require hospitalization (15). Although the importance of RSV as a cause of pneumonia and brochiolitis in young children is well recognized (21), the most serious morbidity and highest mortality associated with both RSV and influenza virus circulation occurs disproportionately among elderly persons (43). The first-line tests used to detect these virus infections in many hospitals are antigen-based immunoassays. It has been demonstrated that antigen immunoassays have exceedingly poor sensitivity in detecting RSV and influenza virus infections in the elderly, seriously limiting their utility for detecting and confirming institutional or community outbreaks (7,13,38). This study was intended to evaluate the performance of viral isolation in cell culture, one-step real-time multiplex reverse transcription-PCR (RT-PCR), and antigen immunoassays for the detection of influenza virus and RSV in respiratory specimens from adults and children during two respiratory virus seasons. MATERIALS AND METHODS Specimens.Upper respiratory tract specimens were collected from 353 individual symptomatic patients during two successive winter respiratory virus seasons encompassing
The processes involved in cell death are complex, and individual techniques measure specific fractions of the total population. The interaction of Candida albicans with amphotericin B was measured with fluorescent probes with different cellular affinities. These were used to provide qualitative and quantitative information of physiological parameters which contribute to fungal cell viability. SYBR Green I and 5,(6)-carboxyfluorescein were used to assess membrane integrity, and bis-(1,3-dibutylbarbituric acid)trimethine oxonol and 3,3-dihexyloxacarbocyanine iodide were used to evaluate alterations in membrane potential. The fluorescent indicators were compared with replication competency, the conventional indicator of viability. By using these tools, the evaluation of the response of C. albicans to amphotericin B time-kill curves delineated four categories which may represent a continuum between alive and dead. The data showed that replication competency (CFU per milliliter) as determined by conventional antifungal susceptibility techniques provided only an estimate of inhibition. Interpretation of fluorescent staining characteristics indicated that C. albicans cells which were replication incompetent after exposure to greater than 0.5 μg of amphotericin B per ml still maintained degrees of physiological function.
Currently, serological assays using either indirect immunofluorescence assay or enzyme-linked immunosorbent assay (ELISA) are performed to evaluate the status of Epstein-Barr virus (EBV) infection in humans. Although these methods are reliable, they are limited to testing an antibody response to a single viral antigen per reaction, thus necessitating a panel of assays to complete the evaluation. In contrast, a new bead-based method (BioPlex 2200; Bio-Rad Laboratories, Hercules, Calif.) can analyze the humoral response to multiple antigens in a single tube. This approach potentially reduces overall cost, turnaround time, and sample volume. The aim of this study was to evaluate the multiplexed EBV serologic assays performed on the BioPlex 2200 platform compared to results of conventional heterophile and ELISA-based assays. A total of 167 nonconsecutive, stored serum samples from adult and pediatric patients submitted for EBV serologic studies were used in the evaluation. Concordance between results generated by the BioPlex 2200 system and conventional assays was calculated. The anti-EA-D assay had the lowest concordance at 91%. The BioPlex 2200 system showed 97% agreement with conventional heterophile and anti-nuclear antigen assays and 92% agreement with the anti-VCA IgG and immunoglobulin M assays. Agreement between the BioPlex 2200 system and conventional testing was 92% with respect to categorization of acute versus nonacute EBV disease. The correlation between these two systems with regard to assignment into one of four categories of EBV status was also good (82%). In summary, there is excellent correlation between contemporary EBV serologic testing and the BioPlex 2200 system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.