Objectives Oligometastatic colorectal cancer benefits of locoregional treatments but data concerning microwave ablation (MWA) are limited and interactions with systemic therapy are still debated. The aim of this study is to evaluate safety and effectiveness of Thermosphere™ MWA (T-MWA) of colorectal liver metastases (CLM) and factors affecting local tumor progression-free survival (LTPFS). Methods In this multi-institutional retrospective study (January 2015–September 2019), patients who underwent T-MWA for CLM were enrolled. Complications according to SIR classification were collected, primary efficacy and LTP were calculated. Analyzed variables included CLM size at diagnosis and at ablation, CLM number, ablation margins, intra-segment progression, chemotherapy before ablation (CBA), variations in size (ΔSDIA-ABL), and velocity of size variation (VDIA-ABL) between CLM diagnosis and ablation. Uni/multivariate analyses were performed using mixed effects Cox model to account for the hierarchical structure of data, patient/lesions. Results One hundred thirty-two patients with 213 CLM were evaluated. Complications were reported in 6/150 procedures (4%); no biliary complications occurred. Primary efficacy was achieved in 204/213 CLM (95.7%). LTP occurred in 58/204 CLM (28.4%). Six-, twelve-, and eighteen-month LTPFS were 88.2%, 75.8%, and 69.9%, respectively. At multivariate analysis, CLM size at ablation (p = 0.00045), CLM number (p = 0.046), ablation margin < 5 mm (p = 0.0035), and intra-segment progression (p < 0.0001) were statistically significant for LTPFS. ΔSDIA-ABL (p = 0.63) and VDIA-ABL (p = 0.38) did not affect LTPFS. Ablation margins in the chemo-naïve group were larger than those in the CBA group (p < 0.0001). Conclusion T-MWA is a safe and effective technology with adequate LTPFS rates. Intra-segment progression is significantly linked to LTPFS. CBA does not affect LTPFS. Anticipating ablation before chemotherapy may take the advantages of adequate tumor size with correct ablation margin planning. Key Points • Thermosphere™-Microwave ablation is a safe and effective treatment for colorectal liver metastases with no registered biliary complications in more than 200 ablations. • Metastases size at time of ablation, intra-segment progression, and minimal ablation margin < 5 mm were found statistically significant for local tumor progression-free survival. • Chemotherapy before ablation modifies kinetics growth of the lesions but deteriorates ablation margins and does not significantly impact local tumor progression-free survival.
Background: An accurate measurement of the target volume is of primary importance in theragnostics of hyperthyroidism Objective: Our purpose was to evaluate the accuracy of a threshold–based isocontour extraction procedure for thyroid tissue volumetry from SPECT-CT. Methods: Cylindrical vials with a fixed volume of 99mTcO4 at different activities were inserted into a neck phantom in two different thickness settings. Images were acquired by orienting the phantom in different positions, i.e., 40 planar images and 40 SPECT-CT. The fixed values of the iso-contouring threshold for SPECT and SPECT-CT were calculated by means of linear and spline regression models. Mean, Median, Standard Deviation, Standard Error, Mean Absolute Percentage Error and Root Mean-Square Error were computed. Any difference between the planar method, SPECT and SPECT-CT and the effective volume was evaluated by means of ANOVA and post-hoc tests. Moreover, planar and SPECT-CT acquisitions were performed in 8 patients with hyperthyroidism, considering relevant percentage differences greater than > 20 % from CT gold standard. Results: Concerning phantom studies, the planar method shows higher values of each parameter than the other two methods. SPECT-CT shows lower variability. However, no significant differences were observed between SPECT and SPECT-CT measurements. In patients, relevant differences were found in 7 out of 9 lesions with the planar method, in 6 lesions with SPECT, but in only one with SPECT-CT. Conclution: Our study confirms the superiority of SPECT in volume measurement if compared with the planar method. A more accurate measurement can be obtained from SPECT-CT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.