The use of Ligasure, associated with the lateral position, results in a gain of time and safety. Furthermore, the average intraoperative bleeding of this series is very low.
Blood loss, a well-known risk factor for morbidity and mortality during liver resection, occurs during parenchymal transection, so many approaches and devices have been developed to limit bleeding. Surgical technique is an important factor in preventing intraoperative and postoperative complications. The aim of the present study was to determine whether the bipolar vessel sealing device allows a safe and careful liver transection, achieving a satisfactory hemostasis thus reducing blood loss and related complications.A total of 30 consecutive patients (18 male, 12 female with a mean age of 63 years) underwent major and minor hepatic resection in which the bipolar vessel sealing device was used without routine inflow occlusion. A crush technique followed by energy application was used to perform the parenchymal transection. No other devices were applied to achieve hemostasis. The bipolar vessel sealing device was effective in 27 cases of hepatic resection. It failed to achieve hemostasis in three patients, all of whom had a cirrhotic liver. Median blood loss was 250 ml (range: 100-1600 ml), and intraoperative blood transfusions were required in five patients (17%). Mean operative time was 200 minutes (range: 140-360 minutes). There was no clinical evidence of postoperative hemorrhage, bile leak, or intraabdominal abscess. The postoperative complication rate was 17%. The bipolar vessel sealing device is a useful tool in standard liver resection in patients with a normal liver parenchyma, but its use should be avoided in cirrhotic livers.
Portal thrombosis should be suspected in patients with fever or abdominal pain after splenectomy. Patients with myeloproliferative disorders and hemolytic diseases are at higher risk, as well as patients with marked splenomegaly. A high index of suspicion, early diagnosis, and prompt anticoagulation therapy are the keys to a successful outcome.
The approach to spleen dissection and hilum section was safe and efficacy in each case, otherwise the use of Ligasure results in a gain of time. Furthermore the average intraoperative bleeding and average transfusion rates of this series were lower in group 2.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.