IntroductionAnastomotic leakage (AL) is one of the major complications after colorectal surgery. Compromised tissue perfusion at the anastomosis site increases the risk of AL. Several cohort studies have shown that indocyanine green (ICG) combined with fluorescent near-infrared imaging is a feasible and reproducible technique for real-time intraoperative imaging of tissue perfusion, leading to reduced leakage rates after colorectal resection. Unfortunately, these studies were not randomised. Therefore, we propose a randomised controlled trial to assess the value of ICG-guided surgery in reducing AL after colorectal surgery.Methods and analysisA multicentre, randomised controlled clinical trial will be conducted to assess the benefit of ICG-guided surgery in preventing AL. A total of 978 patients scheduled for colorectal surgery will be included. Patients will be randomised between the Fluorescence Guided Bowel Anastomosis group and the Conventional Bowel Anastomosis group. The primary endpoint is clinically relevant AL (defined as requiring active therapeutic intervention or reoperation) within 90 days after surgery. Among the secondary endpoints are 30-day clinically relevant AL, all-cause postoperative complications, all-cause and AL-related mortality, surgical and non-surgical reinterventions, total surgical time, length of hospital stay and all-cause and AL-related readmittance.Ethics and disseminationThis protocol has been approved by the Medical Ethical Committee Leiden-Den Haag-Delft (METC-LDD) and is registered at ClinicalTrials.gov and trialregister.nl. The results of this study will be reported through peer-reviewed publications and conference presentations.Trial registration numberNCT04712032; NL7502.
Background: Robotic liver surgery represents the most recent evolution in the field of minimally-invasive liver surgery. For planning and guidance of liver resections, surgeons currently rely on preoperative 2-dimensional (2D) CT and/or MR imaging and intraoperative ultrasonography. Translating 2D images into digital 3-dimensional (3D) models may improve both preoperative planning and surgical guidance. The da Vinci® robotic surgical system is a platform suitable for the integration of multiple imaging modalities into one single view. In this study, we describe multimodal imaging options and introduce the Robotic Liver Surgery Cockpit; Methods: in-house developed software was used and validated for segmentation and registration to create a virtual reality 3D model of the liver based on preoperative imaging. The accuracy of the 3D models in the clinical setting was objectively assessed in 15 patients by measuring tumor diameters and subjectively with a postoperative conducted questionnaire; Results: Implementation and applicability of the 3D model in the surgical cockpit was feasible in all patients and the quality of the 3D reconstructions was high in 14 (93%) of cases. Tumor diameters measured on CT and/or MR imaging were comparable to automated measurements using the segmentation software and 3D models; Conclusions: the 3D model was successfully incorporated in the robotic surgery console as part of a multimodality imaging platform and aided the surgeon in planning and guidance of the resection. Future studies should focus on further automation of 3D rendering and progress into augmented reality.
Background Indocyanine green near-infrared fluorescence bowel perfusion assessment has shown its potential benefit in preventing anastomotic leakage. However, the surgeon's subjective visual interpretation of the fluorescence signal limits the validity and reproducibility of the technique. Therefore, this study aimed to identify objective quantified bowel perfusion patterns in patients undergoing colorectal surgery using a standardized imaging protocol. Method A standardized fluorescence video was recorded. Postoperatively, the fluorescence videos were quantified by drawing contiguous region of interests (ROIs) on the bowel. For each ROI, a time-intensity curve was plotted from which perfusion parameters (n = 10) were derived and analyzed. Furthermore, the inter-observer agreement of the surgeon’s subjective interpretation of the fluorescence signal was assessed. Results Twenty patients who underwent colorectal surgery were included in the study. Based on the quantified time-intensity curves, three different perfusion patterns were identified. Similar for both the ileum and colon, perfusion pattern 1 had a steep inflow that reached its peak fluorescence intensity rapidly, followed by a steep outflow. Perfusion pattern 2 had a relatively flat outflow slope immediately followed by its plateau phase. Perfusion pattern 3 only reached its peak fluorescence intensity after 3 min with a slow inflow gradient preceding it. The inter-observer agreement was poor-moderate (Intraclass Correlation Coefficient (ICC): 0.378, 95% CI 0.210–0.579). Conclusion This study showed that quantification of bowel perfusion is a feasible method to differentiate between different perfusion patterns. In addition, the poor-moderate inter-observer agreement of the subjective interpretation of the fluorescence signal between surgeons emphasizes the need for objective quantification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.