The aim of the present study is to evaluate the intra- and inter-observer agreement in assessing the renal function by means of 99mTc-MAG3 diuretic renography. One hundred and twenty adults were enrolled in the study. One experienced and one junior radiographer processed the renograms twice by assigning manual and semi-automated regions of interest. The differential renal function (DRF, %), time to maximum counts for the right and left kidney (TmaxR-TmaxL, min) and time to half-peak counts (T1/2, min) were calculated. The Bland–Altman analysis (bias±95% limits of agreement), Lin’s concordance correlation coefficient and weighted Fleiss’ kappa coefficient were used to assess agreement. Based on the Bland–Altman analysis, the intra-observer repeatability results for the experienced radiographer using the manual and the semi-automated techniques were 0.2 ± 2.6% and 0.3 ± 6.4% (DRF), respectively, −0.01 ± 0.24 and 0.00 ± 0.34 (TmaxR), respectively, and 0.00 ± 0.26 and 0.00 ± 0.33 (TmaxL), respectively. For the junior radiographer, the respective results were 0.5 ± 5.0% and 0.8 ± 9.4% (DRF), 0.00 ± 0.44 and 0.01 ± 0.28 (TmaxR), and 0.01 ± 0.28 and −0.02 ± 0.44 (TmaxL). The inter-observer repeatability for the manual method was 0.6 ± 5.0% (DRF), −0.10 ± 0.42 (TmaxR) and −0.05 ± 0.38 (TmaxL), and for the semi-automated method −0.2 ± 9.1% (DRF), 0.00 ± 0.31 (TmaxR) and −0.05 ± 0.40 (TmaxL). The weighted Fleiss’ kappa coefficient for the T1/2 assessments ranged between 0.85–0.97 for both intra- and inter-observer repeatability with both methods. These findings suggest a very good repeatability in DRF assessment with the manual method—especially for the experienced observer—but a less good repeatability with the semi-automated approach. The calculation of Tmax was also operator-dependent. We conclude that reader experience is important in the calculation of renal parameters. We therefore encourage reader training in renal scintigraphy. Moreover, the manual tool seems to perform better than the semi-automated tool. Thus, we encourage cautious use of automated tools and adjunct validation by manual methods where possible.
Objective To investigate the influence of colour scales on the interpretation of [ 68 Ga]Ga-PSMA-11 PET/CT for the diagnosis of recurrent prostate cancer.Methods 50 consecutive patients who underwent [ 68 Ga]Ga-PSMA-11 PET/CT for recurrent prostate cancer were selected for this retrospective study. The scans were randomised, anonymised and read by five different readers first in the visually nonlinear colour scale 'PETrainbow'. Scans were then rerandomised and read in the visually linear colour scale 'hot-metal new'. For each scan in each colour scale the numbers of pathological, equivocal and benign lesions were noted. Scans where the majority of readers (≥3) reported at least one PETpositive lesion were recorded as 'pathological'. Patientlevel sensitivity was obtained by composite standard with 14.8 ± 1.2 months of follow-up. ResultsIncreased numbers of lesions per patient were reported for all readers in PET-rainbow compared to hot-metal new (37.4 ± 15.2 vs. 33.9 ± 16.4, respectively, P = 0.0005). On a per-patient basis, 43 scans were rated pathological in PET-rainbow, compared to 39 in hot-metal new. Follow-up was available for 30 patients confirming 26 pathological scans with positive follow-up in PET-rainbow, and 23 in hot-metal new. Three pathological scans were missed in hot-metal new. Patient-level sensitivity was higher for PET-rainbow (0.96) compared to hot-metal new (0.85). Inter-reader reliability was higher for hot-metal new (Fleiss κ = 0.76) compared to PET-rainbow (Fleiss κ = 0.60). ConclusionUse of PET-rainbow was associated with improved lesion detection and sensitivity compared to hot-metal new, although at cost of reduced inter-rater agreement. Consequently, the use of PET-rainbow for clinical routine and future studies involving [ 68 Ga] Ga-PSMA-11 is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.