Objectives To demonstrate the value of three-dimensional (3D) ultrasound in the diagnosis of uterine malformations and its concordance with magnetic resonance imaging (MRI). Methods (kappa index, 0.880 (95% CI, )). Discrepancies in diagnosis betweenthe two techniques occurred in four cases. There was very good concordance in the diagnosis of associated findings (kappa index, 0.878 (95% CI,
Aims:We studied the effectiveness of three-dimensional (3D) ultrasonography in the diagnosis of uterine malformations.Methods: 175 patients with clinical or ultrasonographic suspicion of uterine malformation were studied between November 2004 and June 2008. In all women we measured uterine volume for processing and later reconstruction of 3D images. Cases in which no anomaly was detected with the 3D technique were excluded from study. A thorough physical genital examination with speculum was done before or after ultrasonography, except in three women with an imperforate hymen. Uterine malformations were recorded in detail, and the findings were catalogued according to the American Fertility Society (AFS) classification. In 32 women magnetic resonance (MR) imaging was also used, and agreement between the two techniques was calculated with the kappa index. Results:The 175 müllerian anomalies we analyzed were diagnosed as agenesis (1 case), unicornuate uterus (1 genuine, 1 communicating), didelphys uterus (4), bicornuate uterus (22), septate uterus (80, 8 with two cervices) and arcuate uterus (68). For 1 unicornuate, 3 bicornuate, 25 septate (4 with two cervices) and 3 arcuate uteri we performed MR imaging. Diagnostic correlation between 3D ultrasonography and MR imaging was obtained in all cases according to the AFS classification (kappa = 100%); concordance was also seen for descriptions of associated uterine malformations except for two cases: 1 bicornuate uterus with the additional presence of a cervical septum as detected by MR imaging, which was not found on hysteroscopy for resection, and 1 septate uterus that appeared to have two cervices on 3D ultrasonography in a patient in whom physical examination was not possible, and in whom MR imaging showed a complete septum with hypointense signals (kappa = 93.45%; 95% confidence interval 80.75-100%).Discussion: Owing to its ability to clearly render contours of anatomical structures, 3D ultrasonography provides detailed images of uterine malformations and yields very similar results to those obtained with MR imaging. For an accurate comparison of the two techniques, ultrasonography should be accompanied by gynecologic physical exploration, since the two methods yield equivalent results for the relation between the uterine cavity and the fundus. MR imaging is especially useful to evaluate the cervix and vagina.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.