Aims: The objective of this study is to create an experimental model of intestinal endometriosis in pigs, which might allow better understanding of deep infiltrating endometriosis and development of new treatment techniques. As secondary objective, we intend to create endometrial implants accessible by transrectal ultrasonography (TRUS).
Background and study aims
Post-polypectomy surveillance interval (SI) is determined based on the number, size, and histology of colorectal polyps. Electronic chromoendoscopy in association with magnifying imaging colonoscopy allows “in vivo” polyp histology prediction. Colorectal polyps ≤ 5 mm can be resected and discarded without pathologic assessment if the endoscopic technology when used with high confidence provides ≥ 90 % agreement between the post-polypectomy SI and the SI based on pathological assessment. The aim of this study was to evaluate the agreement between the post-polypectomy SI based on flexible spectral color imaging enhancement (FICE) chromoendoscopy in association with magnified imaging and the pathology-based SI.
Patients and methods
Each diagnosed colorectal polyp received a histology prediction (neoplastic or non-neoplastic) based on the FICE capillary-vessel pattern classification. Each prediction was classified as high or low confidence. SI based on the FICE prediction was compared to the pathology-based SI recommendation according to the US Multi-Society Task Force on Colorectal Cancer guideline. Sensitivity, specificity and accuracy of FICE in diagnosing neoplastic lesions were compared with the pathology assessment. Interobserver and intraobserver agreement for FICE-based SI predictions was evaluated using the kappa coefficient.
Results
A total of 267 polyps had histology prediction assessed with high confidence in 136 patients. Sensitivity of FICE was 98.7 % (95 % CI: 93.5 – 99.3) and specificity was 62.5 % (95 % CI: 43.6 – 78.9). Prediction accuracy was 94.4 % (95 % CI: 88.6 – 96 – 1) in differentiating between neoplastic and non-neoplastic lesions. Therefore, magnifying FICE colonoscopy-based SI recommendation was consistent with pathological assessment in 88.3 % of general cases (95 % CI: 82.1 – 92.6) and in 89.7 % (95 % CI: 83 – 94.5) of the high-confidence evaluation cases. The intraobserver agreement value for FICE-based SI predictions was 0.87 (high-confidence evaluations), and the interobserver agreement values were 0.78 (high- and low-confidence evaluations) and 0.82 (high-confidence evaluations) (95 % CI: 0.79 – 0.95).
Conclusions
FICE-based SI demonstrated 89.7 % concordance with the pathology-based SI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.