Fiber optic Fabry-Perot sensors have been developed whose optical reflectance varies with optical cavity depth (pressure) or with change in a material's refractive index (temperature). These sensors employ a unique combination of features: they are interrogated by an LED; they are designed to operate within a single reflectance cycle; and their returned light is analyzed by a dichroic ratio technique. The sensors use a step index glass fiber and are relatively insensitive to absolute light levels and fiber bending. They have an expanded linear operating range and can be built for low cost disposable applications. Sensor performance meets or exceeds established medical requirements.
SUMMARY Heart rates, blood pressures, and functional responses to submaximal, maximal and postexertional treadmill testing are presented for a group of 704 healthy, asymptomatic aircrewmen referred to the USAF School of Aerospace Medicine. The THE INTERPRETATION OF ELECTROCARDIO-GRAPHIC CHANGES in response to exercise testing is of established value in the early detection, diagnosis, and subsequent management of coronary atherosclerotic heart disease (CAD).'`The major emphasis placed on interpretation of the exercise electrocardiogram (ECG) has, however, tended to de-emphasize the value and significance of other commonly acquired exercise performance measurements (i.e., heart rate, blood pressure, and functional capacity). These latter measurements are currently attracting renewed attention as part of an effort to improve the overall sensitivity and specificity of exercise testing. Recent reports have suggested that maximal oxygen consumption,6 functional aerobic capacity estimated from maximal treadmill time,7 8 maximal and submaximal heart rate and blood pressure,9-" and the maximal heart rate-blood pressure product,'2 may also be useful indices for identifying the presence and/or severity of CAD in patients.The value of any measurement in providing useful diagnostic information from treadmill testing depends upon: a) the accuracy and completeness with which the measurement has been made in healthy individuals (the reference values); and b) the effectiveness with which certain limits of the measurement (discriminant values) separate healthy individuals from those with known health disorders.'3 Previously published studies have reported reference values based on the response of healthy individuals to treadmill testing. Unfortunately, a majority of these studies were based on a small sample size, and statistics based on them are less likely to provide a true estimate of population parameters than is a comparable study based on a larger number. In the remaining few studies with a larger sample size, data for both submaximal and postexertional treadmill responses are fragmentary and incomplete. Hence, the practicing clinician has not had a complete and readily available set of reference values for use with his application of treadmill exercise testing.The purpose of the present report is to establish a complete set of reference values for the response of healthy men indicated measurements are individually described by the use of percentiles. These data provide the practicing clinician with an accurate and complete description of the response of healthy men to treadmill exercise.to submaximal, maximal, and postexertional treadmill testing. In addition to diagnostic use, these reference values serve as a basis for monitoring individuals during treadmill testing to assure patient safety. Finally, this study may provide the basis for subsequent studies which seek to establish discriminant values that separate healthy individuals from those with specific health disorders.
Materials and MethodsThe United States Air Forc...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.