Recent confirmation of intrinsic bacterial contamination of 10% povidoneiodine solution has raised questions regarding the bactericidal mechanism of iodophors and the possibility for survival of vegetative bacterial cells in iodophor solutions. In this laboratory investigation, five different species were exposed to various dilutions of three commercial preparations of 10% povidone-iodine solution; survival was assessed after exposure for time periods varying between 0 and 8 min. All brands of povidone-iodine solution tested demonstrated more rapid killing of Staphylococcus aureus and Mycobacterium chelonei at dilutions of 1:2, 1:4, 1:10, 1:50, and 1:100 than did the stock solutions. S. aureus survived a 2-min exposure to full-strength povidone-iodine solution but did not survive a 15-s exposure to a 1:100 dilution of the iodophor. Both stock and dilute preparations of 10% povidone-iodine solution demonstrated rapid bactericidal action against Klebsiella pneumoniae, Pseudomonas cepacia, and Streptococcus mitis.
From March 5, 1986 to September 4, 1987, Acinetobacter baumannii (AB) was isolated from blood or vascular catheter-tip cultures of 75 patients in five intensive care units at a hospital in New Jersey. To identify risk factors for AB bacteremia in the intensive care units, a case-control study was conducted. Characteristics of 72 case-patients were compared with those of 37 controls. Case-patients were more likely than controls to have had peripheral arterial catheters (odds ratio (OR) = 7.0, p less than 0.001), mechanical ventilation (OR = 5.8, p less than 0.001), hyperalimentation (OR = 5.7, p less than 0.001), or pulmonary arterial catheters (OR = 3.9, p less than 0.001). Arterial catheters were used with reusable pressure transducers for intravascular pressure monitoring. A logistic regression analysis identified four independent risk factors: transducers, ventilation, hyperalimentation, and days of transducer use at an insertion site. The strongest influence on the risk of AB bacteremia was exerted by number of days of transducer usage. Cultures of 70 transducer diaphragms or domes, 42 in-use and 28 in-storage, were positive for AB in 21% and 46%, respectively. Plasmid analysis showed that patient blood cultures and transducer isolates were identical. Transducers were wiped with alcohol in the units between patient uses. Since reusable transducers appeared to be the source of this outbreak, it is recommended that reusable transducers receive either high level disinfection or sterilization between patient uses.
To determine the risk factors associated with toxic-shock syndrome (TSS) in menstruating women, we conducted a retrospective telephone study of 52 cases and 52 age-matched and sex-matched controls. Fifty-two cases and 44 controls used tampons (P < 0.02). Moreover, in case-control pairs in which both women used tampons, cases were more likely than controls to use tampons throughout menstruation (42 of 44 vs. 34 of 44, respectively; P < 0.05). There were no significant differences in brand of tampon used, degree of absorbency specified on label, frequency of tampon change, type of contraceptive used, frequency of sexual intercourse, or sexual intercourse during menstruation. Fourteen of 44 cases had one or more definite or probable recurrences during a subsequent menstrual period. In a separate study, Staphylococcus aureus was isolated from 62 of 64 women with TSS and from seven of 71 vaginal cultures obtained from healthy controls (P < 0.001).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.