Background: The objective of this study was to assess the therapeutic and prognostic impact of integrating18F-fluorodeoxyglucose (18-FDG) positron emission tomography (PET)/computed tomography (CT) into work-up (WU) at initial staging of patients with head and neck squamous cell carcinoma (HNSCC). Method: 477 consecutive patients (414M/63F, mean age 62.3 ± 9.7 years) with newly diagnosed HNSCC who underwent pre-treatment 18-FDG PET/CT were retrospectively included. The 18-FDG PET/CT stage (sPET) was compared to the conventional work-up stage (sCWU). A group of cancer specialists determined whether integrating PET/CT into WU at initial staging had an impact on the therapeutic decision, classifying the clinical impact as high (change in therapeutic modality), medium (change in the radiotherapy or surgical procedure), or low (modification of TNM staging and/or detection of synchronous cancer without high or medium impact). Three-year overall survival (OS) was considered as primary endpoint of the prognostic analysis. Results: 18-FDG PET/CT had a clinical impact in 221 patients (46.3%) with a medium or high impact on management in 94 (19.5%) patients. Medium and high impact of 18-FDG PET/CT was statistically equivalent between sCWU-stage I/II and III/IV subgroups (p = 0.02). 42 patients were PET/CT-upstaged from early stage I/II to advanced stage III/IV and had a significantly lower 3-year OS than those with concordant CWU and 18-FDG PET/CT early stage (54.8 vs. 82.6%, p = 0.001). Conclusion: This study demonstrated that implementing 18-FDG PET/CT in the initial WU of HNSCC provides valuable staging information with a better prognostic stratification. Patient management was modified for any disease stage, even for early stage I-II, with consequences on survival.
position. Comparison of registration method demonstrated OF and A X nR X /R X indices (x = 30% to 50%SUVmax) were significantly higher with ER vs. RR in NTP (p < 0.03), but not in TP. For patient position, the OF and A X nR X /R X indices were higher in TP than in NTP when RR was used with a trend toward significance, particularly for x=40%SUVmax (0.50±0.22 vs. 0.31 ± 0.13, p = 0.094).
Conclusion:Our study suggested that PET/CT acquired in TP improves results in the localization of FDG hotspots in HNSCC. If TP is not possible, using an ER method is significantly more accurate than RR for overlap estimation.
ObjectiveThe diagnosis of chronic thromboembolic pulmonary hypertension (CTEPH) is a major challenge as it is a curable cause of pulmonary hypertension (PH). Ventilation/Perfusion (V/Q) lung scintigraphy is the imaging modality of choice for the screening of CTEPH. However, there is no consensus on the criteria to use for interpretation. The aim of this study was to assess the accuracy of various interpretation criteria of planar V/Q scintigraphy for the screening of CTEPH in patients with PH.MethodsThe eligible study population consisted of consecutive patients with newly diagnosed PH in the Brest University Hospital, France. Final diagnosis (CTEPH or non-CTEPH) was established in a referential center on the management of PH, based on the ESC/ERS guidelines and a minimum follow-up of 3 years. A retrospective central review of planar V/Q scintigraphy was performed by three nuclear physicians blinded to clinical findings and to final diagnosis. The number, extent (sub-segmental or segmental) and type (matched or mismatched) of perfusion defects were reported. Sensitivity and specificity were evaluated for various criteria based on the number of mismatched perfusion defects and the number of perfusion defects (regardless of ventilation). Receiver operating characteristic (ROC) curves were generated and areas under the curve (AUC) were calculated for both.ResultsA total of 226 patients with newly diagnosed PH were analyzed. Fifty six (24.8%) were diagnosed with CTEPH while 170 patients (75.2%) were diagnosed with non-CTEPH. The optimal threshold was 2.5 segmental mismatched perfusion defects, providing a sensitivity of 100 % (95% CI 93.6–100%) and a specificity of 94.7% (95%CI 90.3–97.2%). Lower diagnostic cut-offs of mismatched perfusion defects provided similar sensitivity but lower specificity. Ninety five percent of patients with CTEPH had more than 4 segmental mismatched defects. An interpretation only based on perfusion provided similar sensitivity but a specificity of 81.8% (95%CI 75.3–86.9%).ConclusionOur study confirmed the high diagnostic performance of planar V/Q scintigraphy for the screening of CTEPH in patients with PH. The optimal diagnostic cut-off for interpretation was 2.5 segmental mismatched perfusion defects. An interpretation only based on perfusion defects provided similar sensitivity but lower specificity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.