A study has been made of the use of polynomial curve fitting for removal of nonlinear background and high-spatial-frequency noise components from Raman spectra. Two variations on polynomial curve fitting through a least-squares calculation are used. One, involving fitting data x values to corresponding y values, was used to approximate background functions, which are subtracted from the original data. For smoothing, a reference matrix of six vectors that contains a unity d.c. level, a ramp made up of x values, a quadratic made up of x2 values, etc., is fitted to a section of data. The reference vectors are scaled by the fit values and added to give the smoothed estimate of a spectral peak. It is demonstrated, with factor analysis as a test procedure, that the background removal procedure does remove nonlinearities that were present in the original data. The smoothing procedure rejects high-spatial-frequency noise without introducing detectable nonlinearities.
We have examined the effect of intensity-axis correction on noise in white light spectra recorded with charge-coupled device (CCD) detectors. Measurements were made with five detectors in Raman spectrometers. Detectors were both liquid-nitrogen and thermoelectrically cooled devices and one room temperature device. Both random and pattern noise have been considered. We used cross-correlation of noise sets to provide an indicator of a fixed pattern in the spectra and an assessment of the efficacy of the correction procedure in removing this pattern. For four of the five detectors intensity-axis correction provided a significant improvement in signal-to-noise ratio. Correction was particularly important for measurements made with lower-cost CCD detectors of the kind proposed for process control instruments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.