The excellent corrosion resistance of titanium and its alloys to physiological chloride solutions is well documented. Occasionally, however, titanium compounds have been found in tissue adjacent to titanium implants. These findings were reported to be unrelated to wear processes, suggesting that either the metal or its passive film was dissolving. The unpredictability of these findings further suggests that preimplantation surface treatments and/or variations in the physiological environment may be factors. T o determine a mechanism by which titanium can be released from an implant, a study was initiated which employed electrochemical techniques, Auger electron spectroscopy (AES), and replica transmission electron microscopy (RTEM). Specifically, the purpose was t o characterize the passive film on titanium and Ti-6A1-4V, and to determine if there is dissolution of the film or metal in a static unstressed state. Passive film behavior of commercially pure titanium, Ti-6A1-4V and nitrided Ti-6A1-4V was studied by anodic polarization and pulse potentiostatic capacitance techniques in Ringer's solution at 37OC with and without physiological additions of several amino acids. Solution Poz, pH, and specimen surface finish were varied to include all probable in v i m conditions. In all tests, potentiostatic anodic polarization of each material yielded potential-current density curves which showed passivity over the entire experimental range. This range greatly exceeded the oxygen-reduction reversible electrode potential. No breakdown potentials were observed. The passive current density was not significantly affected by varying the experimental parameters. AES as well as charge and capacitance measurements showed that the electtochemical reaction which occurred was growth of the passive film. The data indicated that the effective electrochemical area of each specimen was less than its geometrical area, and was dependent on both pH and surface finish. The findings of this study showed that, under static conditions, titanium and Ti-6A1-4V should withstand exposure to physiological chloride solutions a t body temperature indefinitely. Furthermore, the findings
The neuroprotective effects of hypothermia have been demonstrated in experimental models and clinical trials. Experimental studies indicate that improved efficacy and broadened indications can be achieved with moderate to deep hypothermia. The TwinFlo catheter was designed to provide very rapid, deep and selective brain cooling with faster cooling rates, and temperatures much lower than those which can be achieved by any other hypothermia device and technique. This report describes the experimental in vivo studies and initial clinical experience with the TwinFlo catheter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.