Respiratory magnetometers are increasingly being used in sleep studies to measure changes in end-expiratory lung volume (EELV), including in obese obstructive sleep apnea patients. Despite this, the accuracy of magnetometers has not been confirmed in obese patients nor compared between sexes. Thus we compared spirometer-measured and magnetometer-estimated lung volume and tidal volume changes during voluntary end-expiratory lung volume changes of 1.5, 1, and 0.5 l above and 0.5 l below functional respiratory capacity in supine normal-weight [body mass index (BMI) < 25 kg/m] and healthy obese (BMI > 30 kg/m) men and women. Two different magnetometer calibration techniques proposed by Banzett et al. [Banzett RB, Mahan ST, Garner DM, Brughera A, Loring SH. J Appl Physiol (1985) 79: 2169-2176, 1995] and Sackner et al. [Sackner MA, Watson H, Belsito AS, Feinerman D, Suarez M, Gonzalez G, Bizousky F, Krieger B. J Appl Physiol (1985) 66: 410-420, 1989] were assessed. Across all groups and target volumes, magnetometers overestimated spirometer-measured EELV by ~65 ml (<0.001) with no difference between techniques (0.07). The Banzett method overestimated the spirometer EELV change in normal-weight women for all target volumes except +0.5 l, whereas no differences between mass or sex groups were observed for the Sackner technique. The variability of breath-to-breath measures of EELV was significantly higher for obese compared with nonobese subjects and was higher for the Sackner than Banzett technique. On the other hand, for tidal volume, both calibration techniques underestimated spirometer measurements (<0.001), with the underestimation being more marked for the Banzett than Sackner technique (0.03), in obese than normal weight (<0.001) and in men than in women (0.003). These results indicate that both body mass and sex affect the accuracy of respiratory magnetometers in measuring EELV and tidal volume.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.