Background
Human adenoviruses are a common group of viruses that cause acute infectious diseases. Human adenovirus (HAdV) 3 and HAdV 7 cause major outbreaks of severe pneumonia. A reliable and practical method for HAdV typing in clinical laboratories is lacking. A simple, rapid and accurate molecular typing method for HAdV may facilitate clinical diagnosis and epidemiological control.
Methods
We developed and evaluated duplex real-time recombinase-aided amplification (RAA) assays incorporating competitive internal controls for detection of HAdV 3 and HAdV 7, respectively. The assays were performed in a one-step in a single tube reaction at 39° for 20 min.
Results
The analytical sensitivities of the duplex RAA assays for HAdV 3 and HAdV 7 were 5.0 and 14.8 copies per reaction, respectively (at 95% probability by probit regression analysis). No cross-reaction was observed with other types of HAdV or other common respiratory viruses. The duplex RAA assays were used to detect 152 previously-defined HAdV-positive samples. These results agreed with those obtained using a published triplex quantitative real-time PCR protocol.
Conclusions
We provide the first report of internally-controlled duplex RAA assays for the detection of HAdV 3 and HAdV 7. These assays effectively reduce the rate of false negative results and may be valuable for detection of HAdV 3 and HAdV 7 in clinical laboratories, especially in resource-poor settings.
BackgroundEnterovirus 71 (EV71) and coxsackievirus A16 (CA16) are the two main etiological agents of Hand, Foot and Mouth Disease (HFMD). Simple and rapid detection of EV71 and CA16 is critical in resource-limited settings.MethodsDuplex real time reverse-transcription recombinase aided amplification (RT-RAA) assays incorporating competitive internal amplification controls (IAC) and visible RT-RAA assays combined with lateral flow strip (LFS) for detection of EV71 and CA16 were developed respectively. Duplex real time RT-RAA assays were performed at 42 °C within 30 min using a portable real-time fluorescence detector, while LFS RT-RAA assays were performed at 42 °C within 30 min in an incubator. Recombinant plasmids containing conserved VP1 genes were used to analyze the sensitivities of these two methods. A total of 445 clinical specimens from patients who were suspected of being infected with HFMD were used to evaluate the performance of the assays.ResultsThe limit of detection (LoD) of the duplex real time RT-RAA for EV71 and CA16 was 47 copies and 38 copies per reaction, respectively. The LoD of the LFS RT-RAA for EV71 and CA16 were both 91 copies per reaction. There was no cross reactivity with other enteroviruses. Compared to reverse transcription-quantitative PCR (RT-qPCR), the clinical diagnostic sensitivities of the duplex real time RT-RAA assay were 92.3% for EV71 and 99.0% for CA16, and the clinical diagnostic specificities were 99.7 and 100%, respectively. The clinical diagnostic sensitivities of the LFS RT-RAA assay were 90.1% for EV71 and 94.9% for CA16, and the clinical diagnostic specificities were 99.7 and 100%, respectively.ConclusionsThe developed duplex real time RT-RAA and LFS RT-RAA assays for detection of EV71 and CA16 are potentially suitable in primary clinical settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.