Using a previous radiograph as a measurement aid helped the user to measure coronal curvature from US images, and improved the accuracy of end-vertebrae selection. US showed high sensitivity and specificity for detecting curve progression, indicating that US may be a suitable, radiation-free alternative for monitoring patients with AIS who have mild or moderate curves.
Intraoral ultrasonography uses high-frequency mechanical waves to study dento-periodontium. Besides the advantages of portability and cost-effectiveness, ultrasound technique has no ionizing radiation. Previous studies employed a single transducer or an array of transducer elements, and focused on enamel thickness and distance measurement. This study used a phased array system with a 128-element array transducer to image dento-periodontal tissues. We studied two porcine lower incisors from a 6-month-old piglet using 20-MHz ultrasound. The high-resolution ultrasonographs clearly showed the cross-sectional morphological images of the hard and soft tissues. The investigation used an integration of waveform analysis, travel-time calculation, and wavefield simulation to reveal the nature of the ultrasound data, which makes the study novel. With the assistance of time-distance radio-frequency records, we robustly justified the enamel-dentin interface, dentin-pulp interface, and the cemento-enamel junction. The alveolar crest level, the location of cemento-enamel junction, and the thickness of alveolar crest were measured from the images and compared favorably with those from the cone beam computed tomography with less than 10% difference. This preliminary and fundamental study has reinforced the conclusions from previous studies, that ultrasonography has great potential to become a non-invasive diagnostic imaging tool for quantitative assessment of periodontal structures and better delivery of oral care.
Violent video constitutes a threat to public security, and effective detection algorithms are in urgent need. In order to improve the detection accuracy of 3D convolutional neural networks (3D ConvNet), a novel violent video detection scheme based on the modified 3D ConvNet is proposed. In this paper, the preprocessing method of data is improved, and a new sampling method by using the key frame as dividing nodes is designed. Then, a random sampling method is adapted to produce the input frame sequence. With experimental evaluations on the crowd violence dataset, the results demonstrate the effectiveness of the proposed new sampling method. For three public violent detection datasets: hockey fight, movies, and crowd violence, individualized strategies are implemented to suit the varied clip length. For the short clips, the 3D ConvNet is constructed by using the uniform sampling method. For the longer clips, the new frame sampling strategy is adopted. The proposed scheme obtains competitive results: 99.62% on hockey fight, 99.97% on movies, and 94.3% on crowd violence. The experimental results show that our method is simple and effective. INDEX TERMS Violent video detection, 3D ConvNet, key frame extraction.
Broadband ultrasound attenuation (BUA) is commonly measured by the spectral ratio method. Conventionally BUA is measured in transverse transmission mode where ultrasound signal is recorded with and without the sample. The spectral ratio method was extended to estimate nBUA (BUA normalized by thickness) in axial transmission mode using spectral amplitudes of the primary reflection and multiple reflection, which echoes more than once between the material interfaces within a layer. We performed three experiments. First, reflections were numerically simulated to verify the accuracy of the method. We then applied the method to estimate attenuation of silicon rubber and the cortex of a bovine femur. The center frequency of the transducers is 2.25 MHz. We obtained 93% accuracy for a simulated data set with 10% random noise after bandpass filtering. For the silicon rubber, 15 measurements were collected and the mean attenuation was 6.33 +/- 0.19 dB MHz(-1) cm(-1). For the bovine bone, eight measurements were performed in the middle portion of the femur. The mean attenuation was 4.91 +/- 0.65 dB MHz(-1) cm(-1) and compared well with those reported in the literature. The results demonstrate that the proposed method has the potential to provide a quick, reliable and robust cortical attenuation assessment in vivo.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.