Magnetic shielding devices with a grid structure of multiple layers of highly magnetically permeable materials (such as permalloy) can achieve remanent magnetic fields at the nanotesla (nT) level or even lower. The remanence of the material inside the magnetic shield, such as the building materials used in the support structure, can cause serious damage to the internal remanence of the magnetic shield. Therefore, it is of great significance to detect the remanence of the materials used inside the magnetic shielding device. The existing test methods do not limit the test environment, the test process is vulnerable to additional magnetic field interference and did not consider the real results of the material in the weak magnetic environment. In this paper, a novel method of measuring the remanence of materials in a magnetic shielding cylinder is proposed, which prevents the interference of the earth’s magnetic field and reduces the measurement error. This method is used to test concrete components, composite materials and metal materials commonly applicated in magnetic shielding devices and determine the materials that can be used for magnetic shielding devices with 1 nT, 10 nT and 100 nT as residual magnetic field targets.
The residual magnetic field in a magnetic shielding device with a multilayer high permeability material (permalloy) structure can be obtained at the nanotesla (nT) level or even lower. At present, in the process of designing a magnetic shielding device, most of the external environmental magnetic field settings are set at the size of the Earth’s environmental magnetic field, but the instruments inside the magnetic shielding device need to be powered, the active compensation coil needs to be powered, and the degaussing coil of passive shielding layer needs to be powered, so substations need to be used around magnetic shielding devices. The magnetic field generated by the substation will affect the magnetic shielding device, so this paper analyzes and measures the magnetic field generated by the substation. Firstly, the finite element model of a substation is established, and the influence of different substations on the environmental magnetic field is analyzed by changing the power. Secondly, the test method of a substation environment magnetic field is determined. Finally, the site test was carried out to measure the influence of different power substations and different distances on the magnetic field, and its influence on the magnetic shielding device was analyzed, which provided an important basis for the construction of the magnetic shielding device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.