BackgroundCardiovascular magnetic resonance (CMR) stress perfusion imaging provides important diagnostic and prognostic information in coronary artery disease (CAD). Current clinical sequences have limited temporal and/or spatial resolution, and incomplete heart coverage. Techniques such as k-t principal component analysis (PCA) or k-t sparcity and low rank structure (SLR), which rely on the high degree of spatiotemporal correlation in first-pass perfusion data, can significantly accelerate image acquisition mitigating these problems. However, in the presence of respiratory motion, these techniques can suffer from significant degradation of image quality. A number of techniques based on non-rigid registration have been developed. However, to first approximation, breathing motion predominantly results in rigid motion of the heart. To this end, a simple robust motion correction strategy is proposed for k-t accelerated and compressed sensing (CS) perfusion imaging.MethodsA simple respiratory motion compensation (MC) strategy for k-t accelerated and compressed-sensing CMR perfusion imaging to selectively correct respiratory motion of the heart was implemented based on linear k-space phase shifts derived from rigid motion registration of a region-of-interest (ROI) encompassing the heart. A variable density Poisson disk acquisition strategy was used to minimize coherent aliasing in the presence of respiratory motion, and images were reconstructed using k-t PCA and k-t SLR with or without motion correction. The strategy was evaluated in a CMR-extended cardiac torso digital (XCAT) phantom and in prospectively acquired first-pass perfusion studies in 12 subjects undergoing clinically ordered CMR studies. Phantom studies were assessed using the Structural Similarity Index (SSIM) and Root Mean Square Error (RMSE). In patient studies, image quality was scored in a blinded fashion by two experienced cardiologists.ResultsIn the phantom experiments, images reconstructed with the MC strategy had higher SSIM (p < 0.01) and lower RMSE (p < 0.01) in the presence of respiratory motion. For patient studies, the MC strategy improved k-t PCA and k-t SLR reconstruction image quality (p < 0.01). The performance of k-t SLR without motion correction demonstrated improved image quality as compared to k-t PCA in the setting of respiratory motion (p < 0.01), while with motion correction there is a trend of better performance in k-t SLR as compared with motion corrected k-t PCA.ConclusionsOur simple and robust rigid motion compensation strategy greatly reduces motion artifacts and improves image quality for standard k-t PCA and k-t SLR techniques in setting of respiratory motion due to imperfect breath-holding.
Purpose To develop a continuous‐acquisition cardiac self‐gated spiral pulse sequence and a respiratory motion‐compensated reconstruction strategy for free‐breathing cine imaging. Methods Cine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath‐holding, using a golden‐angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 × 8 k‐space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low‐rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1–5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole‐heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self‐gating (SPARCS) was compared to that from a standard ECG‐gated breath‐hold balanced steady‐state free precession (bSSFP) cine sequence. Results The self‐gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, –0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold‐standard bSSFP technique. Conclusion SPARCS successfully images cardiac function without the need for ECG gating or breath‐holding. With an 8‐second data acquisition per slice, whole‐heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free‐breathing acquisition.
To develop a free-breathing cardiac self-gated technique that provides cine images and B + 1 slice profile-corrected T 1 maps from a single acquisition. Methods: Without breath-holding or electrocardiogram gating, data were acquired continuously on a 3T scanner using a golden-angle gradient-echo spiral pulse sequence, with an inversion RF pulse applied every 4 seconds. Flip angles of 3° and 15° were used for readouts after the first four and second four inversions. Self-gating cardiac triggers were extracted from heart image navigators, and respiratory motion was corrected by rigid registration on each heartbeat. Cine images were reconstructed from the steady-state portion of 15° readouts using a low-rank plus sparse reconstruction. The T 1 maps were fit using a projection onto convex sets approach from images reconstructed using slice profile-corrected dictionary learning. This strategy was evaluated in a phantom and 14 human subjects. Results: The self-gated signal demonstrated close agreement with the acquired electrocardiogram signal. The image quality for the proposed cine images and standard clinical balanced SSFP images were 4.31 (±0.50) and 4.65 (±0.30), respectively. The slice profile-corrected T 1 values were similar to those of the inversion-recovery spinecho technique in phantom, and had a higher global T 1 value than that of MOLLI in human subjects. Conclusions: Cine and T 1 mapping using spiral acquisition with respiratory and cardiac self-gating successfully acquired T 1 maps and cine images in a single acquisition without the need for electrocardiogram gating or breath-holding. This dual-excitation flip-angle approach provides a novel approach for measuring T 1 while accounting for B + 1 and slice profile effect on the apparent T * 1. K E Y W O R D S cardiac MRI, cine, dictionary learning, self-gating, spiral trajectory, T 1 mapping | 83 ZHOU et al.
To develop and evaluate a high spatial resolution (1.25 × 1.25 mm 2 ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease. Methods: Whole-heart high-resolution spiral perfusion pulse sequences and corresponding motion-compensated reconstruction techniques for both interleaved single-slice (SS) and simultaneous multi-slice (SMS) acquisition with or without outer-volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion-compensated L1-SPIRiT and SMS-Slice-L1-SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5-point scale (5, excellent; 1, poor). Results: High-quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75[2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4,4], P = .95). SMS image quality was improved using SMS-Slice-L1-SPIRiT as compared to SMS-L1-SPIRiT (P < .05 for both reviewers). Conclusion:We demonstrated the successful implementation of whole-heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.