Reflections of LED light cause unwanted noise effects called specular reflection (SR) on colonoscopic images. The aim of this study was to seek answers to the following two questions. (a) How are the texture features used in automatic detection of polyps affected by the interpolation on specular reflections? (b) If they are affected does it really affect the classification performance? In order to answer these questions, we used 610 colonoscopy images, and divided each image into tiles whose sizes were 32‐by‐32 pixels. From these tiles, we selected the ones without any specular reflection. We added different shape and size specular reflections cropped from real images onto the reflection‐free tiles. We then used the nearest neighbors, bilinear and bicubic interpolation techniques on the tiles on which SRs were added. On these tiles we extracted 116 texture features using 3 second‐order approaches, and 4 first‐order statistics. First, we used paired sample t test. Second, we performed automatic classification of polyps and background using random forest and k nearest neighbors (k‐NN) approaches using the texture features for different combinations of specular reflections added on the tiles from the polyp or background. The results showed that depending on the size of specular reflection, interpolation can cause a significant difference between the texture features that were coming from reflection‐free tiles and the same tiles on which interpolation was performed. In addition, we note that bicubic interpolation may be preferred to eliminate specular reflection when texture features are used for background and polyp discrimination.
Computer-aided detection is an integral part of medical image evaluation process because examination of each image takes a long time and generally experts’ do not have enough time for the elimination of images with motion artifact (blurred images). Computer-aided detection is required for both increasing accuracy rate and saving experts’ time. Large intestine does not have straight structure thus camera of the colonoscopy should be moved continuously to examine inside of the large intestine and this movement causes motion artifact on colonoscopy images. In this study, images were selected from open-source colonoscopy videos and obtained at Kayseri Training and Research Hospital. Totally 100 images were analyzed half of which were clear. Firstly, a modified version of histogram equalization was applied in the pre-processing step to all images in our dataset, and then, used Laplacian, wavelet transform (WT), and discrete cosine transform-based (DCT) approaches to extract features for the discrimination of images with no artifact (clear) and images with motion artifact. The Laplacian-based feature extraction method was used for the first time in the literature on colonoscopy images. The comparison between Laplacian-based features and previously used methods such as WT and DCT has been performed. In the classification phase of our study, support vector machines (SVM), linear discriminant analysis (LDA), and k nearest neighbors (k-NN) were used as the classifiers. The results showed that Laplacian-based features were more successful in the detection of images with motion artifact when compared to popular methods used in the literature. As a result, a combination of features extracted using already existing approaches (WT and DCT) and the Laplacian-based methods reached 85% accuracy levels with SVM classification approach
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.