Primary stenting with balloon expandable stents in the infrapopliteal arteries does not outway the benefit of PTA alone with the application of modern hydrophilic balloon catheters in patients with CLI.
In dialysis access fistulas and grafts, percutaneous transluminal angioplasty (PTA) is frequently followed by restenosis development, which results in repeated periodical re-interventions. The technique of drug-eluting balloon (DEB) angioplasty has shown promising results in the treatment of femoropopliteal arteriosclerotic lesions. In contrast to arteriosclerotic arteries, dialysis access vessels host unfavorable hemodynamics due to the direct conduction of high-pressure fluid into a low-pressure system. Hence, the beneficial effect of DEB angioplasty may be limited in this system. However, a first prospective randomized trial on 40 patients with arteriovenous fistula or graft stenoses exhibited a significantly higher 6-month primary patency of the treated lesions after DEB angioplasty than after uncoated balloon angioplasty. Despite such a positive reference, general recommendations regarding the value of DEBs in dialysis access vessels cannot be considered as serious unless large randomized controlled trials have been performed.
The RFA Guardian is a comprehensive application for high-performance patient-specific simulation of radiofrequency ablation of liver tumors. We address a wide range of usage scenarios. These include pre-interventional planning, sampling of the parameter space for uncertainty estimation, treatment evaluation and, in the worst case, failure analysis. The RFA Guardian is the first of its kind that exhibits sufficient performance for simulating treatment outcomes during the intervention. We achieve this by combining a large number of high-performance image processing, biomechanical simulation and visualization techniques into a generalized technical workflow. Further, we wrap the feature set into a single, integrated application, which exploits all available resources of standard consumer hardware, including massively parallel computing on graphics processing units. This allows us to predict or reproduce treatment outcomes on a single personal computer with high computational performance and high accuracy. The resulting low demand for infrastructure enables easy and cost-efficient integration into the clinical routine. We present a number of evaluation cases from the clinical practice where users performed the whole technical workflow from patient-specific modeling to final validation and highlight the opportunities arising from our fast, accurate prediction techniques.Radiofrequency ablation (RFA) of liver malignancies has become an important alternative therapy for patients who disqualify for standard surgical treatment or are in an early tumor stage 1,2 . When surgical resection is not feasible, RFA is the preferred treatment option for small liver tumors 1,2 . Moreover, patient recovery after surgical resection takes longer and post-procedural quality of life is lower than after RFA 2 .While many more options for local cancer treatment exist (e.g. Cryo Ablation 3 , Irreversible Electroporation 4 or hyperthermia in conjunction with other treatment methods 5,6 ), the clincial routine prefers RFA (or, occasionally, microwave ablation) treatment for smaller liver tumors. Although microwave ablation has become more prevalent in the past years, no statistically significant difference in survival rates compared to RFA of smaller lesions (diameter below 3.5 cm) in the liver could be found 7,8 .In RFA, interventional radiologists (IR) destroy malignant cells using percutaneous probes that induce heating in a locally delimited region around a tumor. Successful treatment is defined as complete ablation of the tumor with a safety margin of destroyed healthy tissue in its immediate vicinity.However, clinical experience with RFA indicates a significant mismatch between expected and observed lesion size, leading to reduced survival rates due to over-treatment with severe injuries (up to 9%) or under-treatment with tumor recurrence 9 (up to 40%). Further, Hildebrand et al. 10 have shown that the survival rates after 1 and 2 years significantly depend on the experience of the IR: Operating experience of 0-2 years resulted in 69...
Bone loss and fractures are common complications after cardiac transplantation (CTP). The aim of this study was to investigate whether intravenous ibandronate is an effective preventive option. Thirtyfive male cardiac transplant recipients received either ibandronate (IBN) 2 mg intravenously every 3 mo or matching placebo (CTR) in addition to 500 mg calcium carbonate and 400 IE vitamin D 3 . Sera were collected at CTP and every 3 mo thereafter. At baseline and 6 and 12 mo, standardized spinal X-rays and BMD measurements were taken. Bone biopsies were taken at CTP and after 6 mo from six patients. In the IBN group, 13% of the patients sustained a new morphometric vertebral fracture compared with 53% in the CTR group (absolute risk reduction [ARR], 40%; relative risk reduction [RRR], 75%; p = 0.04). BMD remained unchanged with IBN treatment but in the CTR group decreased at the lumbar spine by 25% and at the femoral neck by 23% (both p < 0.0001) over the 1-yr period. Serum bone resorption markers carboxyterminal telopeptide region of type I collagen (sCTX) and TRACP 5b were significantly increased in the CTR group and decreased in the IBN group at all time points compared with baseline. In contrast, both osteocalcin and bone-specific alkaline phosphatase levels showed, after a similar decrease over the first 3 mo in both groups, a marked rise in the CTR subjects and steadily declining levels in the IBN patients throughout the remainder of the study period. Three paired biopsies were available from each group. Despite the small sample size, a difference in the relative change of eroded surface (68% in the CTR versus 223% in the IBN group, p < 0.05) could be shown. Intravenous IBN reduced fractures, preserved bone mass, and prevented uncoupling of bone formation and resorption after CTP. The favorable effects on bone turnover were also supported by histomorphometric findings.
A 55-year-old male with peripheral arterial disease underwent angioplasty of the right lower limb arteries via antegrade femoral access. Angio-Seal® closure device was used to treat the puncture site, whereby the intravascular sealing anchor accidentally embolized into the malleolar region of the right posterior tibial artery. Successful retrieval of the anchor was accomplished by a SpiderFX embolic protection device. This technique may be a useful approach to retrieve embolized foreign bodies via endovascular access.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.