The FilmArray respiratory virus panel detects 15 viral agents in respiratory specimens using polymerase chain reaction. We performed FilmArray respiratory viral testing in a core laboratory at a regional children's hospital that provides service 24 hours a day 7 days a week. The average and median turnaround time were 1.6 and 1.4 hours, respectively, in contrast to 7 and 6.5 hours documented 1 year previously at an on-site reference laboratory using a direct fluorescence assay (DFA) that detected 8 viral agents. During the study period, rhinovirus was detected in 20% and coronavirus in 6% of samples using FilmArray; these viruses would not have been detected with DFA. We followed 97 patients with influenza A or influenza B who received care at the emergency department (ED). Overall, 79 patients (81%) were given oseltamivir in a timely manner defined as receiving the drug in the ED, a prescription in the ED, or a prescription within 3 hours of ED discharge. Our results demonstrate that molecular technology can be successfully deployed in a nonspecialty, high-volume, multidisciplinary core laboratory.
Objectives: Utilization of emergency departments (EDs) for pediatric mental health (MH) complaints is increasing. These patients require more resources and have higher admission rates than those with nonpsychiatric complaints.Methods: A multistage, multidisciplinary process to reduce length of stay (LOS) and improve the quality of care for patients with psychiatric complaints was performed at a tertiary care children's hospital's ED using Lean methodology. This process resulted in the implementation of a dedicated MH team, led by either a social worker or a psychiatric nurse, to evaluate patients, facilitate admissions, and arrange discharge planning. We conducted a retrospective, before-and-after study analyzing data 1 year before through 1 year after new process implementation (March 28, 2011). Our primary outcome was mean ED LOS.Results: After process implementation there was a statistically significant decrease in mean ED LOS (332 minutes vs. 244 minutes, p < 0.001). An x-bar chart of mean LOS shows special cause variation. Significant decreases were seen in median ED LOS (225 minutes vs. 204 minutes, p = 0.001), security physical interventions (2.0% vs. 0.4%, p = 0.004), and restraint use (1.7% vs. 0.1%, p < 0.001). No significant change was observed in admission rate, 72-hour return rate, or patient elopement/agitation events. Staff surveys showed improved perception of patient satisfaction, process efficacy, and patient safety.Conclusions: Use of quality improvement methodology led to a redesign that was associated with a significant reduction in mean LOS of patients with psychiatric complaints and improved ED staff perception of care.ACADEMIC EMERGENCY MEDICINE 2016;23:440-447 © 2016 by the Society for Academic Emergency Medicine M ental health (MH) disorders are common in children, with an estimated 13%-20% of children in the United States experiencing a mental disorder in a given year.1-5 They also are increasing, with a reported 24% increase in inpatient MH and substance abuse admissions among children from 2007 to 2010 6 and an 80% increase in hospital stays for children with mood disorders from 1997 to 2010. 7 Despite this increasing prevalence, psychiatric services for children in many parts of the country are limited, 8 leaving many with unmet psychiatric care needs. 9Nationally, pediatric emergency department (ED) visits for MH issues increased by over 20% between 2001 and 2010. 10 Pediatric EDs (PEDs) have also seen high volumes of patients presenting with psychiatric crises, with 3.3% of PED visits related to MH issues in one
We have measured plasma volume and cardiac index in rats after 50% isovolemic exchange transfusion with human hemoglobin cross-linked between the alpha-chains with bis(3,5-dibromosalicyl)fumarate (alpha alpha Hb) and with bovine hemoglobin modified with polyethylene glycol (PEGHb). alpha alpha Hb and PEGHb differ in colloid osmotic pressure (23.4 and 118.0 Torr, respectively), oxygen affinity (oxygen half-saturation pressure of hemoglobin = 30.0 and 10.2 Torr, respectively), viscosity (1.00 and 3.39 cP, respectively), and molecular weight (64,400 and 105,000, respectively). Plasma volume was measured by Evans blue dye dilution modified for interference by plasma hemoglobin. Blood volumes in PEGHb-treated animals were significantly elevated (74.0 +/- 3.5 ml/kg) compared with animals treated with alpha alpha Hb (49.0 +/- 1.2 ml/kg) or Ringer lactate (48.0 +/- 2.0 ml/kg) or with controls (58.2 +/- 1.9 ml/kg). Heart rate reduction after alpha alpha Hb exchange is opposite to that expected with blood volume contraction, suggesting that alpha alpha Hb may have a direct myocardial depressant action. The apparently slow elimination of PEGHb during the 2 h after its injection is a consequence of plasma volume expansion: when absolute hemoglobin (concentration x plasma volume) is compared for PEGHb and alpha alpha Hb, no difference in their elimination rates is found. These studies emphasize the need to understand blood volume regulation when the effects of cell-free hemoglobin on hemodynamic measurements are evaluated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.