BackgroundPhotoimmunodetection, in which monoclonal antibodies [mAbs] are labeled with fluorescent dyes, might have clinical potential for early detection and characterization of cancer. For this purpose, the dye should be coupled in an inert way to mAb. In this study, different equivalents of IRDye800CW, a near-infrared fluorescent dye, were coupled to 89Zr-labeled cetuximab and bevacizumab, and conjugates were evaluated in biodistribution studies. Radiolabeled mAbs were used to allow accurate quantification for assessment of the number of dye groups that can be coupled to mAbs without affecting their biological properties.Methods89Zr-cetuximab and 89Zr-bevacizumab, containing 0.5 89Zr-desferal group per mAb molecule, were incubated with 1 to 10 eq IRDye800CW at pH 8.5 for 2 h at 35°C, and 89Zr-mAb-IRDye800CW conjugates were purified by a PD10 column using 0.9% NaCl as eluent. HPLC analysis at 780 nm was used to assess conjugation efficiency. In vitro stability measurements were performed in storage buffer (0.9% NaCl or PBS) at 4°C and 37°C and human serum at 37°C. 89Zr-mAb-IRDye800CW conjugates and 89Zr-mAb conjugates (as reference) were administered to nude mice bearing A431 (cetuximab) or FaDu (bevacizumab) xenografts, and biodistribution was assessed at 24 to 72 h after injection.ResultsConjugation efficiency of IRDye800CW to 89Zr-mAbs was approximately 50%; on an average, 0.5 to 5 eq IRDye800CW was conjugated. All conjugates showed optimal immunoreactivity and were > 95% stable in storage buffer at 4°C and 37°C and human serum at 37°C for at least 96 h. In biodistribution studies with 89Zr-cetuximab-IRDye800CW, enhanced blood clearance with concomitant decreased tumor uptake and increased liver uptake was observed at 24 to 72 h post-injection when 2 or more eq of dye had been coupled to mAb. No significant alteration of biodistribution was observed 24 to 48 h after injection when 1 eq of dye had been coupled. 89Zr-bevacizumab-IRDye800CW showed a similar tendency, with an impaired biodistribution when 2 eq of dye had been coupled to mAb.ConclusionUsage of 89Zr-mAbs allows accurate quantification of the biodistribution of mAbs labeled with different equivalents of IRDye800CW. Alteration of biodistribution was observed when more than 1 eq of IRDye800CW was coupled to mAbs.
IRDye800CW and zirconium-89 ((89)Zr) have very attractive properties for optical imaging and positron emission tomography (PET) imaging, respectively. Here we describe a procedure for dual labeling of mAbs with IRDye800CW and (89)Zr in a current good manufacturing practice (cGMP)-compliant way. IRDye800CW and (89)Zr are coupled inertly, without impairment of immunoreactivity and pharmacokinetics of the mAb. Organ and whole-body distribution of the final product can be assessed by optical and PET imaging, respectively. For this purpose, a minimal amount of the chelate N-succinyldesferrioxamine (N-sucDf) is first conjugated to the mAb. Next, N-sucDf-mAb is conjugated with IRDye800CW, after which the N-sucDf-mAb-IRDye800CW is labeled with (89)Zr. After each of these three steps, the product is purified by gel filtration. The sequence of this process avoids unnecessary radiation exposure to personnel and takes about 5 h. The process can be scaled up by the production of large batches of premodified mAbs that can be dispensed and stored until they are labeled with (89)Zr.
BackgroundWe describe a new method for biodistribution studies with IRDye800CW fluorescent antibody probes. This method allows the quantification of the IRDye800CW fluorescent tracer in percentage of injected dose per gram of tissue (% ID/g), and it is herein compared to the generally used reference method that makes use of radioactivity.MethodsCetuximab was conjugated to both the near-infrared fluorophore IRDye800CW and/or the positron emitter 89-zirconium, which was injected in nude mice bearing A431 human tumor xenografts. Positron emission tomography (PET) and optical imaging were performed 24 h post-injection (p.i.). For the biodistribution study, organs and tumors were collected 24 h p.i., and each of these was halved. One half was used for the determination of probe uptake by radioactivity measurement. The other half was homogenized, and the content of the fluorescent probe was determined by extrapolation from a calibration curve made with the injected probe.ResultsTumors were clearly visualized with both modalities, and the calculated tumor-to-normal tissue ratios were very similar for optical and PET imaging: 3.31 ± 1.09 and 3.15 ± 0.99, respectively. Although some variations were observed in ex vivo analyses, tumor uptake was within the same range for IRDye800CW and gamma ray quantification: 15.07 ± 3.66% ID/g and 13.92 ± 2.59% ID/g, respectively.ConclusionsThe novel method for quantification of the optical tracer IRDye800CW gives similar results as the reference method of gamma ray quantification. This new method is considered very useful in the context of the preclinical development of IRDye800CW fluorescent probes for optical molecular imaging, likely contributing to the selection of lead compounds that are the most promising for clinical translation.
Tubulysins are highly toxic tubulin-targeting agents with a narrow therapeutic window that are interesting for application in antibody-drug conjugates (ADC). For full control over drug-antibody ratio (DAR) and the effect thereof on pharmacokinetics and tumor targeting, a dual-labeling approach was developed, wherein the drug, tubulysin variants, and the antibody, the anti-HER2 monoclonal antibody (mAb) trastuzumab, are radiolabeled.131 I-radioiodination of two synthetic tubulysin A analogues, the less potent TUB-OH (IC 50 > 100 nmol/L) and the potent TUB-OMOM (IC 50 , $1 nmol/L), and their direct covalent conjugation to 89 Zrtrastuzumab were established. Radioiodination of tubulysins was 92% to 98% efficient and conversion to N-hydroxysuccinimide (NHS) esters more than 99%; esters were isolated in an overall yield of 68% AE 5% with radiochemical purity of more than 99.5%. Conjugation of 131 I-tubulysin-NHS esters to 89 Zr-trastuzumab was 45% to 55% efficient, resulting in ADCs with 96% to 98% radiochemical purity after size-exclusion chromatography. ADCs were evaluated for their tumor-targeting potential and antitumor effects in nude mice with tumors that were sensitive or resistant to trastuzumab, using ado-trastuzumab emtansine as a reference. ADCs appeared stable in vivo. An average DAR of 2 and 4 conferred pharmacokinetics and tumor-targeting behavior similar to parental trastuzumab. Efficacy studies using single-dose TUB-OMOM-trastuzumab (DAR 4) showed dose-dependent antitumor effects, including complete tumor eradications in trastuzumab-sensitive tumors in vivo. TUB-OMOM-trastuzumab (60 mg/kg) displayed efficacy similar to ado-trastuzumab emtansine (15 mg/kg) yet more effective than trastuzumab. Our findings illustrate the potential of synthetic tubulysins in ADCs for cancer treatment. Cancer Res; 74(20); 5700-10. Ó2014 AACR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.