Calcareous sediments are prominent throughout the low-latitudinal offshore environment and have been known to be problematic for offshore foundation systems. These fascinating soils consist largely of the skeletal remains of single-celled marine organisms (plankton and zooplankton) and can be as geologically complex as their onshore siliceous counter parts. To enable an adequate understanding of their characteristics, in particular, their intra-granular micro-structure, it is important that geotechnical engineers do not forget about the multifaceted biological origins of these calcareous sediments and the different geological processes that created them. In this paper, the 3D models of soils grains generated from micro-computed tomography scans, scanning electeron microscope images, and optical microscope images of two calcareous sediments from two different depositional environments are presented and their geotechnical implications discussed. One is a coastal bioclastic sediment from Perth, Western Australia that is geologically similar to carbonate sediments typically used in micro-mechanics and particle crushing studies in the literature. The other is a hemipelagic sediment from a region of the North West Shelf of Australia that has historically been geotechnically problematic for engineers. The results show there is a marked difference between coastal bioclastic and hemipelagic sediments in terms of geological context and the associated particle micro-structures. This brings into question whether a coastal bioclastic calcareous sediment is a good micro-mechanical substitute for a hemipelagic one.
Many offshore structures currently in use are supported by piles with large length-to-diameter aspect ratios, because it is well known that such foundations can hold large forces and moments. In environments where long piles are not suitable, structures will use foundations with very low aspect ratios such as skirts and mats. Capacity of long piles has been studied for decades and is well documented, whilst more recent tests have also addressed the behaviour of skirts, mats, and other low-aspect ratio foundations. The vertical and lateral capacity of mid-size foundations, with aspect ratios between one and five, has generally been thought too low for the requirements of most offshore structures. However, in recent years, structures of increasingly different shapes and sizes have been used in offshore environments, such as water-based renewable energy sources or marginal oil and gas platforms. In many of these cases, the usage of a low aspect ratio foundation could significantly reduce installation and transportation costs. Limited studies have been performed on such foundations, and most of the existing work uses only analytical and numerical solutions. Geotechnical centrifuge tests and corresponding numerical analyses were started at Texas A&M University and were continued at the University of Cambridge on the lateral capacity of piles with an aspect ratio of two in normally consolidated clay. Piles were loaded under both pure rotation and a mix of rotation and translation. This work is relevant to offshore structures requiring foundations that are strong but easily installed and cost-efficient, specifically structures secured with piles that experience point loads either through or above the water. It is also of interest for structures in difficult environments, such as areas too shallow or sedimentary for long piles or too fragile for skirts and mats.
and the wonderful experiences the City of Philadelphia has to offer. From the early days of modern geotechnical engineering, sharing field experiences of the performance of geostructures-dams, foundations, tunnels, landfills-in the form of case histories has driven the advancement of knowledge for the geo-profession. Starting in 1984, Professor Shamsher Prakash formalized this tradition and organized the First International Conference on Case Histories in Geotechnical Engineering. This conference brought together more than 190 engineers from 30 countries to share their experiences, learn from each other, and advance the profession. By 2013, the 7th conference in this series drew nearly 320 engineers from 40 countries spanning the globe, culminating in symposia to honor Ralph B. Peck and Clyde Baker. But the essence of the conference had not changed: to advance our profession through shared engineering judgment. Geo-Congress 2019 continues this tradition and features experiences and observations from hundreds of geoengineering projects. The conference includes a wide range of informative technical and panel sessions, short courses, and workshops. Join us in celebration of our geo-accomplishments!
gco component of centrifugal acceleration for a known reference gravity vector, gõ, on the vertical reference plane, R ge magnitude of Earth's gravity vector, gẽ α angle between a centrifuge gravity vector, g, and the centrifuge radial coordinate, r αo angle between a reference gravity vector, gõ, and the centrifuge radial coordinate, r β angle between a centrifuge gravity vector, g, and the local vertical coordinate, z βo angle between the local vertical coordinate axis, z, and the centrifuge radial coordinate, r ξ angle between the local vertical coordinate axis, z, and the centrifuge radial coordinate, r gx component of centrifuge gravity, g, in model local horizontal coordinate, x gz component of centrifuge gravity, g, in model local vertical coordinate, z M Mass of centrifuge basket αb Angle of centrifuge basket relative to centrifuge radial coordinate, r Lb Distance between basket hinge and the basket mass, M Rb Distance between centrifuge axis, Y, and basket hinged Distance between the basket centreline and the basket mass, M L Angle between the centreline of the basket and the project line, L, between the basket hinge and the basket mass, M Δαb Angle between the centreline of the basket and the project line, L, between the basket hinge and the basket mass, M α2D
Geotechnical centrifuge tests were conducted to examine the behavior of low aspect ratio piles and caissons in clayey soils subjected to high moment loading. Model piles with aspect ratio of two were tested in the 150g-ton centrifuge at Rensselaer Polytechnic Institute. Results include moment-inclination and force-displacement response for different loading conditions. Numerical studies were also performed consisting of three dimensional finite element simulations in order to predict capacities. The comparisons are performed in terms of the total resistance that is exerted by the soil on the caisson. This paper focuses on presenting the ultimate bearing capacity factors including both experimental and numerical results. In addition, results are compared to a series of studies available in the literature, which include upper bound solutions and experimental results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.