Throughout the central nervous system extracellular adenosine serves important neuroprotective and neuromodulatory functions. However, current understanding of the in vivo regulation and effects of adenosine is limited by the spatial and temporal resolution of available measurement techniques. Here, we describe an enzyme-linked microelectrode array (MEA) with high spatial (7500 µm(2)) and temporal (4 Hz) resolution that can selectively measure extracellular adenosine through the use of self-referenced coating scheme that accounts for interfering substances and the enzymatic breakdown products of adenosine. In vitro, the MEAs selectively measured adenosine in a linear fashion (r(2)=0.98±0.01, concentration range=0-15 µM, limit of detection =0.96±0.5 µM). In vivo the limit of detection was 0.04±0.02 µM, which permitted real-time monitoring of the basal extracellular concentration in rat cerebral cortex (4.3±1.5 µM). Local cortical injection of adenosine through a micropipette produced dose-dependent transient increases in the measured extracellular concentration (200 nL: 6.8±1.8 µM; 400 nL: 19.4±5.3 µM) [P<0.001]. Lastly, local injection of dipyridamole, which inhibits transport of adenosine through equilibrative nucleoside transporter, raised the measured extracellular concentration of adenosine by 120% (5.6→12.3 µM) [P<0.001]. These studies demonstrate that MEAs can selectively measure adenosine on temporal and spatial scales relevant to adenosine signaling and regulation in normal and pathologic states.
OBJECTIVE Many low-risk unruptured intracranial aneurysms (UIAs) are followed for growth with surveillance imaging. Growth of UIAs likely increases the risk of rupture. The incidence and risk factors of UIA growth or de novo aneurysm formation require further research. The authors retrospectively identify risk factors and annual risk for UIA growth or de novo aneurysm formation in an aneurysm surveillance protocol. METHODS Over an 11.5-year period, the authors recommended surveillance imaging to 192 patients with 234 UIAs. The incidence of UIA growth and de novo aneurysm formation was assessed. With logistic regression, risk factors for UIA growth or de novo aneurysm formation and patient compliance with the surveillance protocol was assessed. RESULTS During 621 patient-years of follow-up, the incidence of aneurysm growth or de novo aneurysm formation was 5.0%/patient-year. At the 6-month examination, 5.2% of patients had aneurysm growth and 4.3% of aneurysms had grown. Four de novo aneurysms formed (0.64%/patient-year). Over 793 aneurysm-years of follow-up, the annual risk of aneurysm growth was 3.7%. Only initial aneurysm size predicted aneurysm growth (UIA < 5 mm = 1.6% vs UIA ≥ 5 mm = 8.7%, p = 0.002). Patients with growing UIAs were more likely to also have de novo aneurysms (p = 0.01). Patient compliance with this protocol was 65%, with younger age predictive of better compliance (p = 0.01). CONCLUSIONS Observation of low-risk UIAs with surveillance imaging can be implemented safely with good adherence. Aneurysm size is the only predictor of future growth. More frequent (semiannual) surveillance imaging for newly diagnosed UIAs and UIAs ≥ 5 mm is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.