The tip of a rod is heated with a torch and brought into contact with the center of a metal sheet. A thermal camera is then used to image the temperature profile of the surface as a function of time. The infrared camera is capable of recording radiometric data with 1 mK resolution in nearly 105 pixels, so thermal diffusion can be monitored with unprecedented precision. With a frame rate of approximately 10 Hz, the pace of the data acquisition minimizes the loss of accuracy due to inevitable cooling mechanisms. We report diffusivity constants equal to 1.23 ± 0.06 cm2/s in copper and 0.70 ± 0.05 cm2/s in aluminum. The behavior is modeled with a straightforward but oddly under-utilized one-dimensional finite difference method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.