We designed this study to determine the predictive value for fluid responsiveness of stroke volume variation (SVV) in patients undergoing one-lung ventilation (OLV), ventilated at different tidal volumes. All patients scheduled for pulmonary lobectomy were randomized into two groups according to their tidal volume [group H: tidal volume 8 ml/kg (n = 36); group L: tidal volume 6 ml/kg (n = 37)]. After starting OLV, volume loading was performed by administration of 500 ml 6% hydroxyethylated starch for 30 min. Hemodynamic variables were measured before and after volume loading using the Vigileo-FloTrac system. Patients in both groups were divided into fluid responders and non-responders, and responders were defined as those who demonstrated an increase in cardiac index ≥15% after volume expansion. The area under the receiver operating characteristic curve for SVV to discriminate between responders and non-responders was 0.776 in group H and 0.648 in group L. The optimal threshold value of SVV was 10.5% (sensitivity, 85.7%; specificity, 66.7%) in group H and 8% (sensitivity, 69.5%; specificity, 64.3%) in group L. We found that SVV could predict fluid responsiveness in patients undergoing OLV with acceptable levels of sensitivity and specificity only when tidal volume is at least 8 ml/kg.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.