Editor-We read with interest the recent article by Schummer and colleagues 1 regarding the use of pre-procedure ultrasound (US) to facilitate central venous (CV) catheterisation. In an observational study investigating 606 procedures, the authors demonstrate that pre-procedure US is superior to landmark methods. The investigators conclude that pre-procedure US offers an alternative to real-time US and are to be congratulated for adding further support to US as an instrument to further patient safety and improve outcomes.We would, however, like to raise the following issues. Although some risk factors for difficult insertion have been recorded, we feel the list is not comprehensive. One of the main complications recorded was the incidence of severe haematoma associated with line insertion. CV cannulation can be safely carried out in the presence of coagulopathy, although an increased risk of haematoma formation in the presence of coagulation deficit has been described. 2 We note that the highest incidence of haematoma formation (2.5%) occurred in the landmark group containing the highest number of cardiac patients. We might speculate that cardiac medications, such as antiplatelet drugs, may be implicated. Based on these factors and the importance of haematoma formation as a measured outcome, we are surprised that normal coagulation and platelet count/ function were not listed as specific inclusion criteria.We would also like to draw attention to the issues raised regarding availability and cost. The authors state 'most practitioners do not have real-time US as an option'. We would suggest that US hardware is widely accessible. A survey of 294 UK anaesthetic departments revealed that 172 of 199 respondents (86%) had ultrasound readily available. 3 The authors also suggest a problem with the 'perceived expense' of real-time US and a fear of 'large investments' in hardware. This is presented as a reason for investigating the use of pre-procedure US. The US machine used in the study utilises an 18 -6 MHz linear probe, which is likely to be suitable for real-time cannulation. As US hardware would be required for both pre-procedure and realtime techniques, we fail to recognise pre-procedure US as a significantly less expensive option. Although pre-procedure US may reduce the costs of disposables associated with CV cannulation (such as sterile probe covers and sterile gel) these items cost very little per procedure. 4 5 The authors identify that 'unnecessary time expenditure' is a complaint against realtime US. Their citation regarding this consists of an opinion survey of members of the Society of Cardiovascular Anesthesiologists. The survey demonstrates that only 113 of 1494 respondents (8.5%) were concerned about a possible time delay when using US. 6 No evidence of actual delay with realtime US is provided. Furthermore, a comprehensive technology appraisal conducted by the National Institute of Health and Care Excellence has concluded that US guided cannulation is a cost effective option and is recommended for electi...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.