The MammoSite radiation therapy system is a novel technique for treatment of patients with early‐stage breast cancer. It was developed to overcome the longer schedules associated with external‐beam radiation therapy. It consists of a small balloon (4 cm in diameter) connected to an inflation channel and a catheter for the passage of a high dose rate 192Ir brachytherapy source. The device is placed into the tumor resection cavity and inflated with a mixture of saline and radiographic contrast agent to a size that fills the cavity. A high dose rate 192Ir source is driven into the balloon center using a remote afterloader to deliver the prescribed dose at a point 1 cm away from the balloon surface. There are several uncertainties that affect the dose distribution in the MammoSite brachytherapy. They include source position deviation, balloon deformation, and the concentration of the contrast medium inside the balloon. The purpose of this study is to investigate the extent of the dose perturbation for various concentrations of the contrast medium in a MammoSite balloon using Monte Carlo simulations and thermoluminescent dosimetry. This study also combines the impact of these uncertainties on the MammoSite treatment efficacy. The current study demonstrates that the combined uncertainties associated with the MammoSite brachytherapy technique — up to the value of 2 mm balloon deformation, 1 mm source deviation, and 15% contrast concentration — have no impact on the tumor control probability.PACS number: 87.53.‐j
The MammoSite breast high dose rate brachytherapy is used in treatment of early-stage breast cancer. The tumour bed volume is irradiated with high dose per fraction in a relatively small number of fractions. Uncertainties in the source positioning and MammoSite balloon deformation will alter the prescribed dose within the treated volume. They may also expose the normal tissues in balloon proximity to excessive dose. The purpose of this work is to explore the impact of these two uncertainties on the MammoSite dose distribution in the breast using dose volume histograms and Monte Carlo simulations. The Lyman-Kutcher and relative seriality models were employed to estimate the normal tissues complications associated with the MammoSite dose distributions. The tumour control probability was calculated using the Poisson model. This study gives low probabilities for developing heart and lung complications. The probability of complications of the skin and normal breast tissues depends on the location of the source inside the balloon and the volume receiving high dose. Incorrect source position and balloon deformation had significant effect on the prescribed dose within the treated volume. A 4 mm balloon deformation resulted in reduction of the tumour control probability by 24%. Monte Carlo calculations using EGSnrc showed that a deviation of the source by 1 mm caused approximately 7% dose reduction in the treated target volume at 1 cm from the balloon surface. In conclusion, accurate positioning of the (192)Ir source at the balloon centre and minimal balloon deformation are critical for proper dose delivery with the MammoSite brachytherapy applicator. On the basis of this study, we suggest that the MammoSite treatment protocols should allow for a balloon deformation of < or = 2 mm and a maximum source deviation of < or = 1 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.