Pulse transformers suitable for high-frequency and high-voltage operations in a traveling-wave tube amplifier (TWTA) had been designed, fabricated, and tested. Two transformers with different operation frequency of 100 and 80 kHz were designed, fabricated, and tested. The transformer with 100-kHz switching frequency had input and output voltages of 250 Vdc and 4.1 kV, respectively. Operating power was 3.06 kW. Achieved power density of the 100-kHz transformers was 22.26 W/cm 3 . The transformer with 80-kHz switching frequency had input and output voltages of 265 Vdc and 4.1 kV, respectively. Normal operating power of the transformer was 1.67 kW. Achieved power density of the 80-kHz transformer was 12.15 W/cm 3 . Three different winding arrangements for the 80-kHz transformer were tested and it was found that the one with a sandwiched primary between secondary windings had the best performance in electrical characteristics. It was possible to reduce the stray capacitance while maintaining low-leakage inductance with the best arrangement. Therefore, the self-resonant frequency was far separated from the operating frequency, and, thus, the new arrangement minimized the self-resonant current that is generally one of source for transformer temperature rise.Index Terms-High-power density, pulse transformer, travelingwave tube amplifier (TWTA).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.